![Olivetti d-Copia 18MF Operation Service Manual Download Page 109](http://html2.mh-extra.com/html/olivetti/d-copia-18mf-operation/d-copia-18mf-operation_service-manual_3804705109.webp)
1-6-13
(4) Removing the bias PWB
1. Remove the cassette and process unit (see page 1-6-2).
2. Remove the left cover (see page 1-6-4).
3. Remove the power supply PWB and high voltage PWB (see page 1-6-12).
4. Stand the machine with the front side up.
5. Remove the connector from the bias PWB.
6. Remove five screws.
7. Remove the bottom cover.
8. Remove two connectors from the bias PWB.
9. Remove the bias PWB.
Figure 1-6-16 Removing the bias PWB
Connector
Connectors
Bottom cover
Bias PWB
Screws
Screws
Y104230-6 Sevice Manual