Diagnostic aids
3-35
FB Edge Erase
This menu item sets the size, in millimeters, of the no print are around a flatbed scan job. Copy jobs will use the
setting or two millimeters, whichever is larger.
To adjust the flatbed edge erase setting, perform the following steps:
1.
In the Configuration menu, select the FB Edge Erase menu item.
2.
Use the
or
to increase or decrease the settings value.
3.
When the desired value is displayed, press
.
Scanner Manual Registration
This item is used to manually register the flatbed and ADF on the MFP’s scanner unit. Registration should be
performed whenever the ADF unit, flatbed unit, or controller card are replaced.
To manually register the ADF perform the following steps:
1.
In the Configuration Menu, scroll to the Scanner Manual Registration menu item.
2.
Press .
3.
Scroll to the Print Quick Test Page menu item.
4.
Press .
5.
To view and adjust the simplex ADF registration, place the quick test page into the ADF, scroll to the Copy
Quick Test Page item and press
.
6.
After the quick test page copies, scroll to ADF and press
.
7.
Scroll to Horizontal Adjust, and press
.
8.
Use the
or
to increase or decrease the settings value.
Note:
Each button press move the margin values one pixel in the respective direction.
9.
Press
to accept the value.
10.
Scroll to Top Edge and press
.
11.
Use the
or
to increase or decrease the settings value.
Note:
pressing
moves the margin up and pressing
moves the margin down.
12.
Press
to accept the value.
To manually register a Duplex ADF, perform the following steps:
1.
In the Configuration Menu, scroll to the Scanner Manual Registration menu item.
2.
Press .
3.
Scroll to the Print Quick Test Page menu item.
4.
Press .
5.
To view and adjust the duplex ADF front side registration, place the quick test pageface up into the ADF,
scroll to the Copy Quick Test Page item and press
.
6.
After the quick test page copies, scroll to ADF Frontside and press
.
7.
Scroll to Horizontal Adjust, and press
.
8.
Use the or
to increase or decrease the settings value.
Note:
Each button press move the margin values one pixel in the respective direction.
9.
Press
to accept the value.
10.
Scroll to Top Edge, and press
.
11.
Use the
or
to increase or decrease the settings value.
Note:
pressing
moves the margin up and pressing
moves the margin down.
12.
Press
to accept the value.
13.
To view and adjust the duplex ADF backside registration, place the quick test pageface down up into the
ADF, scroll to the Copy Quick Test Page item and press
.
14.
After the quick test page copies, scroll to ADF Backside, and press
.
15.
Scroll to Horizontal Adjust, and press
.
Y112730-2
Summary of Contents for d-Color MF920
Page 1: ...SERVICE MANUAL Copiatrici Copiers d Color MF920 d Color MF923 Code Y112730 2...
Page 10: ...x Service Manual Y112730 2...
Page 15: ...Notices and safety information xv Y112730 2...
Page 16: ...xvi Service Manual Y112730 2...
Page 18: ...xviii Service Manual Y112730 2...
Page 22: ...xxii Service Manual Y112730 2...
Page 124: ...2 80 Service Manual Y112730 2...
Page 198: ...3 74 Service Manual Y112730 2...
Page 302: ...4 104 Service Manual Y112730 2...
Page 305: ...Locations 5 3 Interior view Y112730 2...
Page 306: ...5 4 Service Manual Printer boards Controller Board Y112730 2...
Page 317: ...Locations 5 15 HVPS Y112730 2...
Page 319: ...Locations 5 17 LVPS Y112730 2...
Page 324: ...6 2 Service Manual Y112730 2...
Page 331: ...Index I 7 Y112730 2...
Page 332: ...UPDATINGSTATUS DATE UPDATEDPAGES PAGES CODE 09 2010 1ST EDITION 332 Y112730 2...