Theory of Operation Ver. 8.0 Jun. 2008
19. Fusing section
1
39
2
Composition/Operation
E. Fusing temperature control during printing.
• Fusing temperature control prevents declining of the image stability as well as reduces
curling of the paper, uneven waxing, offset, etc., according to the paper type to be used.
• Fusing temperature control can be set from “Service mode/machine/fusing temperature”.
• Adjust the fusing temperature at heating side first. If the further adjustment is necessary,
adjust on the pressure side.
F.
Temperature control during low power mode
• The IH coil stops to reduce the power consumption at low power mode and make tem-
perature control by lowering the fusing temperature.
• Usually the pressure roller stops at low power mode though, the roller rotates slightly
every certain period to prevent the brush roller from being distorted.
*1: The temperature of the pressure roller is not controlled because the IH coil is turned
OFF.
Paper type
Heated site
(Heating roller temperature)
Pressured side
(Fusing pressure roller temperature)
Plain paper
- 20
q
C to + 5
q
C (step: 5
q
C)
- 20
q
C to + 5
q
C (step: 5
q
C)
OHP
Thick paper 1, 1+
Thick paper 2
Thick paper 3
Thick paper 4
Postcards
Envelopes
- 5
q
C to + 5
q
C (step: 5
q
C)
- 5
q
C to + 5
q
C (step: 5
q
C)
Machine
models
Pressure/
spacing of
fusing
pressure roller
Rotation of
fusing
pressure
roller
Set temperature of
heating roller
(Degree
centigrade)
Set temperature of
fusing pressure
roller (Degree
centigrade)
Set temperature of
soaking roller
(Degree
centigrade)
Spacing
Stop
- *1
2
100
160
MF
550/
MF
45
0
Y107522-3 Theory of Operation