11. Display will show
for
stage 2 time
. Stage 2 only works for menus 01-20
(For menus 21-40 skip to the Pre-alarm). Use up and down keys or keypad to enter
the time in whole minutes. Entering 0 will eliminate stage 2 and skip you past the
rest of the stage 2 parameters. Press ‘next’ key to advance.
12. Display will show
for
stage 2 Temperature
. Use up and down keys or
keypad to enter the Temperature. Press the ‘next’ key to advance.
13. Display will show
for
stage 2 fan
. Use up and down keys to scroll between
Hi and Lo fans. Press ‘next’ key to advance. Best results are achieved with the fans
on HI.
14. Display will show
for
Pre-Alarm
. Use the up and down keys to select the
Pre-Alarm in whole minutes (0 to 30). Example: A pre alarm value of 1 will sound an
alarm 1 minute before the time expires. Press ‘next’ key to advance.
15. Display will show
for
Vent
. Use the up and down keys to scroll closed,
open or 1-14 minutes. Venting example: A vent time of one minute will make the
vent open one minute before the end of the menu program. Press ‘next’ key to
complete program and return to the menu prompt.
16.
Enter the next menu number to be programmed or press cancel to leave
programming mode.
Summary of Contents for NC
Page 32: ...690 NC2 0690S20050 9 1 ELECTRICAL SUB PANEL Rev 2 27 09 ...
Page 34: ...690 NC2 0690S20051 10 1 FRONT PANEL Revised 12 10 2012 ...
Page 36: ...690 NC2 0690S20052 11 1 DOOR ASSEMBLY Rev 12 10 2012 ...
Page 38: ...690 NC2 0690S20053 12 1 HOUSING CHAMBER ASSEMBLY ...
Page 40: ...690 NC2 0690S20054 13 1 WATER SYSTEM ASSEMBLY ...
Page 42: ...690 NC2 0690S20055 14 1 DAMPER CONTROL ASSEMBLY ...
Page 44: ...690 NC2 0690S20056 15 1 208 240V WIRING DIAGRAM 0690D12025 Revised 2 27 09 ...
Page 45: ...690 NC2 0690S20056 15 2 375 480V WIRING DIAGRAM 0690D12026 Revised 2 27 09 ...
Page 46: ...690 NC2 0690S20056 15 3 INTERFACE BOARD SCHEMATICS ...