INTERIZING YOUR OLIVER LEGACY ELITE II
Objective Summary
x
Prepare the unit for winterization when camper will not be in use to protect
from freezing
Tools/Items Required:
x
Ratchet & 1 1/8” socket
x
Antifreeze hand pump
x
Hose measuring 3’ or less
x
Non-toxic RV antifreeze
Winterization Protocol
1)
Disconnect all external water sources from the travel trailer.
2)
Ensure that the black & gray water tanks are empty.
3)
Ensure that the travel trailer is level.
4)
Turn the water heater off at the switch panel located under the pantry. Let the
water inside the water heater cool before draining to avoid serious injury.
5)
Turn the diverter valve on the back of the water heater to the “by-pass” position
to halt the flow of water into the water heater. (See pictures for exact
positioning) The water heater can be accessed through either of the curbside
service access compartments inside the unit. On some models, there is an access
hatch located between the two curbside access compartments near the floor that
will also allow you access to the valve.