0619S20050
5-2
The motor has “Stalled” and cannot be restarted.
Possible
Causes
•
The overload relay has tripped. Allow the relay about five minutes to cool
and attempt to restart the divider.
The divider is not cutting properly.
Possible
Causes
•
Dough scraps and flour have accumulated between the blade holder and
the thrust plate. See “Cleaning” under maintenance.
•
Check the oil level in the tank, refill if necessary see “Lubrication” under
maintenance.
•
Check to see if the calibrating screw on the control valve has become loose.
If it has, check the procedure for setting the pressure, given under “Adjusting
the Pressure Relief on the Control Valve” in the maintenance section.