7
Dust Collection
The 6” dust collection port (A, Figure 4) is
located below the outfeed table. Typically flex
hose is used to run from this point to a central
trunk line.
Note: Do not operate the jointer without dust
collection.
Electrical Connections
! WARNING
Electrical connections and wiring must be
performed by a certified electrician. The
machine must be properly grounded.
Failure to comply may cause serious
injury!
This jointer can be 1 or 3-Phase based on
your order and is wired for 220 volt. If on 3
phase you need to switch from 220V to 440V,
have a certified electrician make the changes.
Make sure the voltage of your power supply
matches the specifications on the motor plate
of the machine.
With 3-Phase power verify the cutter head is
turning in the proper direction. If rotation is
incorrect, swap two of the phases to reverse.
Note
: If running from a phase converter
ensure the ‘high leg’ of the converter does not
feed the control circuit.
Stop/Start Switch
Attach the Stop/Start switch (Figure 3) to holes
‘A’ using the supplied bolts
Figure 1
Figure 2 (3 Phase)
Figure 3