23
Message
E0
E1
L0
HI
DF
OFF
Door
ENS
Descrip on
Ambient Probe Failure
Defrost Probe Failure
Low Temperature Alarm
High Temperature Alarm
Defros ng in Progress
Standby
Open Door
Energy Saving Mode
Opera ng Message
To switch off, press the ON/OFF bu on (informa on "OFF" on the display, equipment off) or disconnect
the plug from the mains. Wait 10 minutes before turning the equipment back on.
4.1.1 ENS (Energy Saving) / ECO Mode (where applicable)
PZOLC0H001
With this command, the equipment has its own characteris cs:
ü
A day and night mode (ENS/ ECO night mode visible on the display). Automa c temperature
adjustment for energy saving without the need to follow the common prac ce of turning the
equipment off;
ü
The products are preserved, for example, at four (4) degrees during the day and at 7 degrees
overnight, according to factory se ng;
ü
The lights and the power saving mode are set to switch on and off according to the me the
door is kept closed. There is, however , a ligh ng bu on if you prefer to keep the light always
on;
ü
Op miza on of automa c defrost;
ü
Reducing power consump on by stopping the fan when it is not needed;
ü
Adjustable cabinet temperature;
ü
The automa c detec on of ice in the evaporator and detec on of lack of gas.
ENS/ ECO – Energy saving – a er 2 hours without opening the door, the equipment
automa cally switches to Energy saving, turning off the light and increasing the set point by + 3°C.
A er 4 hours, the cabinet will return to the normal temperature. To switch from ENS/ ECO to normal
opera on, simply open the door for more than 10 seconds or press the ES bu on on the digital
(switch ON, light always on).
When fully loading the cabinet, it is possible for the alarm to go off a er 2 hoours if it has not reached
the set temperature, and “Hi” is visible in the display. Press the “mute” bu on to turn the alarm off
and wait 12 hours for the temperatureto stabilize. If the set temperature has not been
reached within this me, please contact our technical service.