The positive cabinets AP 600 PO / APA 600 PO are intended for storage and preservation fresh products. 
AP 600 PO// AP600 A PO are vertical refrigerated cabinets for professional utilization. 
 

1. Recycling instructions  

 
1.1-

 

Recycling of packaging 
 

The packaging, protect the cabinet during the carriage. The material used are reused. 
Help us to protect the environment and recycling the packaging, contact the municipal services to obtain information’s how 
to proceed.  
Be careful with the place storage of packaging material, it must be away from the children, trying to put them in places of 
recycling. 
 

1.2-

 

Recycling of used equipments 
 

 

This  appliance  is  labeled  in  accordance  with 
European  Directive  2012/19/CE  concerning  used 
electrical and electronic appliances (waste electrical 
and  electronic  equipment  –  WEEA).  The  guideline 
determines  the  framework  for  the  return  and 
recycling  of  used  appliances  as  applicable 

throughout  the  EU.  By  ensuring  the  correct  disposal  of  this 
equipment,  the  user  is  helping  to  prevent  potential  negative 
consequences for the environment and public health. 
 
The appliance is not without value and must not be treated as an 
ordinary  domestic  waste.  Remove  them  in  an  environmentally 
responsible will recover valuable raw materials.

 

 
ADVICE!  
 

In equipments out of service must: 

- Disconnect the cabinet. 
-  Cut  the  electric  cabe  and  move  them  away  from  the 
equipment like the power plug. 
-  The  cooling  equipments  have  refrigerant  fluid,  it  must  be 
correctly eliminate. 
 
Be  careful  for  don’t  damage  the  tube  where  circulate  the 
cooling fluid, until your recycling. 

 

 

2.

 

Safety instructions and warning 

 

After having acquires this cabinet, read the recommendations carefully and always keep them within easy reach. 
Must keep the instructions in a safe place and accessible to the user, the instructions manual have important information’s 
like the installation, utilization and maintenance of the equipment. Save all the documentation for utilization or for other 
person who will adquire the equipment. 
 

2.1- Recomendations of safety and for use 
 

 

Before connecting the cabinet, check whether there as been any damage to the cable and plug during transport. 

 

This  device  belongs  to  climatic  class  4  (indicated  in  the  plate  of  characteristics)  for  what  the  allowable  room 
temperature in which the device should function will have to be b16 ºC and +32º C. 

 

Do not touch the cabinet with wet or damp hands or feet. 

 

This device is not foreseen to be used by people (including children) whose physical capacities, sensorial or mental 
are  reduced,  or  people  with  lack  of  experience  or  knowledge,  except  if  they  will  be  able  to  benefit,  through  a 
responsible person for its security, of a monitoring or previous instructions relative to the use of the device. 

 

Never disconnect the cabinet from the power point by pulling the power cable. Use the ribbed area to grip the plug. 

 

Never use electronic device inside this device (warmer…) 

Danger of explosion.

 

 

Never use mechanical devices for accelerate de defrosting, different than recommended by the manufacturer. (e.g. 
Defrosting or cleaning the equipment with a steam cleaner! The steam could reach the electric elements and cause 
short circuit. Danger of electric shock. 

 

For defrosting and cleaning, must disconnect the cabinet. 

Summary of Contents for AP 600

Page 1: ...e A PO Termóstato Thermostat Termostato Carel R600a Instruções de Manutenção e Utilização Instructions de Manutention et Utilization Operating and Maintenance Instructions Instrucciones de Utilización y Mantenimiento 01 07 2016_ECO ...

Page 2: ... Alarme de temperatura baixa LO 6 7 Dimensões 6 8 Ficha de produto 7 9 Circuito Eléctrico 23 Declaração de conformidade 24 1 Recycling instructions 1 1 Recycling of packing 8 1 2 Recycling of used equipments 8 2 Safety instructions and warming 2 1 Recomendattions for use and safety 8 2 2 Technical safety 9 3 Installation 3 1 Unpacking the cabinet 9 3 2 Locating the cabinet 9 3 3 Connecting the cab...

Page 3: ... 16 7 Dimensions 16 8 Fiche technique 16 9 Circuit électrique 23 Déclaration de conformite 24 1 Instrucciones de reciclaje 1 1 Reciclage de la embalage 18 1 2 Reciclage de los equipos utilizados 18 2 Instrucciones de seguridad y advertencia 2 1 Instrucciones de uso y securidad 18 2 2 Seguridad técnica 19 3 Instalación 3 1 Desembalaje del armario 19 3 2 Emplazamiento del armario 19 3 3 Conexión elé...

Page 4: ...o do equipamento com a respectiva ficha de rede Os equipamentos de frio contêm fluído refrigerante Que deve ser correctamente eliminados Ter cuidado para não danificar a tubagem do fluido refrigerante até à sua correcta reciclagem 2 Instruções de segurança e aviso Deverá ler atentamente estas instruções antes de colocar o equipamento em funcionamento Deverá manter estas instruções num local seguro...

Page 5: ... interior do mesmo A substituição do cabo eléctrico e outras reparações só podem ser efectuadas por serviços técnicos qualificados de forma a evitar perigo Instalações e reparações inadequadas podem acarretar vários perigos para o utilizador 3 Instalação 3 1 Desembalar o Armário Desembale o Armário removendo a embalagem assim como as suas protecções e estrado Ter em atenção o local de armazenagem ...

Page 6: ...rmite regular a temperatura de 1 ºC a 10 ºC O termóstato vai bloqueado de fábrica permitindo apenas ajustar a temperatura desejada set point Para programar a temperatura desejada pressionar a tecla set alterar para o valor pretendido com as teclas e e voltar a pressionar a tecla set para fixar o valor O display indicará a temperatura interna do armário Nota O diferencial está regulado a 3ºC de fáb...

Page 7: ...go 6 5 Alarme de temperatura alta HI Verificar a acumulação de gelo no evaporador Verificar se o ventilador está a funcionar Verificar se a porta não ficou demasiado tempo aberta 6 6 Alarme de temperatura baixa LO Verificar a programação do termóstato Se depois destas verificações a anomalia subsistir deverá ser pedida assistência ao seu revendedor ou directamente aos nossos serviços técnicos Nest...

Page 8: ...nergético Anual 1014 Consumo energético em 24 Horas 2 778 Volume Liquido Do s Compartimento s 474 L Fluido refrigerante contido no equipamento Tipo de fluido R600a Designação Inflamável PAG Potencial de Aquecimento Global 3 Carga de Fluido 0 070 Kg Precauções Especificas Para Otimizar A Sua Eficiência Energética Manutenção preventiva Regular Cumprir com as instruções do manual Não deixar a porta a...

Page 9: ...e cooling equipments have refrigerant fluid it must be correctly eliminate Be careful for don t damage the tube where circulate the cooling fluid until your recycling 2 Safety instructions and warning After having acquires this cabinet read the recommendations carefully and always keep them within easy reach Must keep the instructions in a safe place and accessible to the user the instructions man...

Page 10: ...s must be done by the manufacturer its service agent or similarly qualified persons in order to avoid hazard 3 Installation 3 1 Unpacking the cabinet Take off the plastic packing and remove the protections and pallet Take care to see that the cabinet packing is placed out of the reach of children If possible try to put the packing in a place where it could be recycled Check whether the cabinet has...

Page 11: ...digital thermostat allows adjusting the temperature from 1ºC to 10ºC in the positive models and 10ºC to 22ºC in the negative models The thermostat is factory locked only permits to adjust the desired temperature set point To program the desired temperature press ON OFF or buttons To lock the keyboard again proceed as stated above and select YES in the LOC function The display will indicate the tem...

Page 12: ...order to avoid a hazard 6 5 High Temperature Alarm HI Check if there is any ice accumulation at the evaporator Check whether the fan is working Check whether the door was open for a long period of time 6 6 Low Temperature Alarm LO Check the thermostat programming If after making these checks the anomaly remains you should ask your retailer for assistance or contact our technical department directl...

Page 13: ... Anual energetic consumptation 1014 Energetic consumptation in 24 hours 2 778 kWh Net volum of the compatment s 474 L Refrigerant fluid of the equipment Type of fluid R600a Designation Inflamable gas GWP Global Warming Potential 3 Fluid Charge 0 070 Kg Specific precautions to optimize their energy efficiency Regular preventive mantenaince Don t leave the door open for a long time Reduce the openin...

Page 14: ...nt précieuses matières premières Avertissement Armoires hors de service Débranchez la fiche Coupé le cáble electric L equipment de refroidissement contenant fluide refrigerant Devrait être bien eliminé Attention pour ne endommager pas le tube du fluide refrigerant 2 Instructions d alerte et sécurité Après avoir acquit cette armoire lire attentivement les recommandations et les garder toujours á po...

Page 15: ...nt son agent de service ou une personne qualifiée afin d éviter tout danger 3 Installation 3 1 Déballage de l armoire Retirer l emballage ainsi que les protections et la palette Il faut veiller au lieu de dépôt de l emballage de l armoire hors de portée des enfants en essayant si possible de le déposer dans un lieu qui permet le recyclage Vérifier si l armoire n a souffert d aucun dommage durant l...

Page 16: ...its soient soigneusement conditionnés Le thermostat digital permet le réglage de la température de 1ºC a 10ºC dans les modèles positifs et 10ºC a 22ºC dans les modèles négatif Le thermostat est bloqué d usine seulement à régler la température désirée Pour programmer la température voulue appuyer sur le bouton set ou La nouvelle température est ainsi enregistrée N B le différentiel est réglé a 3ºC ...

Page 17: ...milaire afin d éviter un danger 6 5 Alarme température haute HI Vérifier l accumulation de glace dans l évaporateur Vérifier si le ventilateur exterieur fonctionne Vérifier si la porte a été trop de temps ouverte 6 6 Alarme température baisse LO Vérifier le réglage du thermostat Si après ces vérifications l anomalie subsiste il sera nécessaire de demander l assistance de votre revendeur Dans ce ca...

Page 18: ...lation de l air à l intérieur de l équipement Ne pas obstruer le ventilateur interne avec de la nourriture RECOMENDACIONES IMPORTANTES Leer atentamente las recomendaciones y guardarlas siempre al alcance de la mano Una instalación adecuada y una utilización racional de acuerdo con las recomendaciones permitirán obtener un mejor funcionamiento del armario Los modelos positivos AP 600 PO APA 600 PO ...

Page 19: ...dad retirando la clavija del enchufe y proceder a su reparación No tocar el armario con las manos o pies húmedos No dejar el armario expuesto a las inclemencias del tiempo lluvia sol etc No deje el envase alejado de los niños Riesgo de asfixia No guarde dentro de l armario productos con propelentes latas de aerosol etc y products explosivos Riesgo d explosión Este dispositivo no se prevé para ser ...

Page 20: ...coincide con la que se indica en la placa de características del aparato Debe de existir una toma de tierra Comprobar que el cable no este enrollado si la longitud no es la adecuado cambiar todo el cable por uno que cubra la distancia del armario al enchufe no utilizar alargo Lo aparato debe ser posicionado de modo a que lo enchufe sea visible 4 Control 4 1 Puesta en marcha Después de un transport...

Page 21: ...tura de la sonda de lo ambiente E1 Rotura de la sonda de descongelación LO Alarma baja temperatura HI Alarma alta temperatura DF Descongelación en curso OFF Standby Un error de instalación puede causar daños a personas animales u otros para los cuales el fabricante no pude ser considerado responsable 5 MANTENIMIENTO Mantener el armario limpio evitar que se acumule polvo y otros materiales en las r...

Page 22: ...geração S A Domicile Rua Armando Marecos Vale d Água de Fora Tremês Representante autorizado Modelo AP 600 PO APA 600 PO Categoría de equipo Vertical Chilled Uso previsto Storage Temperatura de funcionamiento Refrigeration Clase climática Temperatura Humedad 4 30ºC 55 Clase eficiencia energética D índice de eficiencia energética 50 IEE 75 Consumo anual de energía 1014 kWh ano Consumo energético en...

Page 23: ...marelo Green Yellow Verte Jaune Verde Amarillo C1 Cabo do compressor Compressor cable Câble du compresseur Cable del compresseur C2 Cabo do ventilador Internal fan cable Câble du ventilateur Cable del ventilador C3 Cabo da resistência de evaporação Evaporation resistance cable Cable de resistence d evaporation RE Resistência de evaporação Evaporation resistance Resistance d evaporation ...