background image

18.2.2004

 Rev. 1.0

Operating instructions

11

4.2.3

Cooking

Set the cooking temperature by means of the thermostat;

When the set temperature is reached, add salt to the water and (if necessary) oil;

Arrange food in baskets and immerse in hot water. (Cooking time depends on
food);

When products are cooked, lift the basket up to drain, shake lightly and then empty
the product into a container or onto a serving plate;

Do not use the appliance if the tank is empty.

Never leave the appliance unattended while in use.

4.2.4

Switching off the appliance

To switch off the pasta cooker turn the thermostat to position 0 (shown in figure 2). At
this point the line indicator light will switch off.

4.2.5

Safety thermostat

The appliance is equipped with a safety thermostat. The safety thermostat trips if the tem-
perature of the heating elements increases excessively (fire protection function). This is a
safety feature in the event of malfunctions, faulty components, or improper use (no water
in the tank, dirty heating elements, etc.).

If the safety thermostat trips, disconnect power to the appliance and proceed as follows:

1.

Wait for about 10 minutes for the water temperature to fall below 90°C.

2.

Reset the safety thermostat as follows:

Open the doors.

Unscrew the nut under the control panel (shown by the arrows in figure 4);

Fig. 4

Insert a slender tool (max. diameter 7 mm) into the hole;

Press the tool until you hear a metallic click.

Refit  the  nut.

3.

Clean the tank and fill with water up to the maximum level.

4.

Turn the appliance on.

If the safety thermostat trips again, call service.

Summary of Contents for metos 700 72/02CPE

Page 1: ...ELECTRIC PASTA COOKERS 700 Grill Series TYPE 72 02CPE 74 02CPE Installation and Operation Manual S N Rev 1 0 ...

Page 2: ......

Page 3: ...ppliance The instructions and hints in this manual will give you a quick and easy start and you will soon note how nice it is to use the Metos equipment All rights are reserved for technical changes You will find the main technical data on the rating plate fixed to the equipment When you need service or technical help please let us know the serial number shown on the rating plate This will make it...

Page 4: ...18 2 2004 Rev 1 0 ...

Page 5: ... Prohibited use Improper use 5 3 2 Construction 5 3 3 Operating principle 6 3 3 1 Operating controls and indicator lights 6 4 Operating instructions 9 4 1 Before use 9 4 1 1 Preparing for use 9 4 2 Using the appliance 10 4 2 1 Filling the tank 10 4 2 2 Switching on the appliance 10 4 2 3 Cooking 11 4 2 4 Switching off the appliance 11 4 2 5 Safety thermostat 11 4 2 6 Emptying the tank 12 4 3 Opera...

Page 6: ...ndings 16 5 4 Storage 16 5 5 Unpacking the appliance 16 5 6 Disposing of packing materials 16 5 7 Positioning 16 5 8 Electrical connections 17 5 8 1 General 17 5 8 2 Connection of the power supply cable Y type to the appliance terminal block 18 5 8 3 Bonding terminal 19 5 9 Water connection 19 5 10 Drain connection 19 5 11 Staff training 19 5 12 Rating plate 20 6 Troubleshooting 21 8 Technical spe...

Page 7: ...serviced by a technically qualified person authorized by the manufacturer and using exclusively genuine original spare parts when replacements are necessary Failure to comply with the foregoing prescriptions may compromise the safety of the ap pliance 1 1 Symbols used in the manual This symbol indicates situations associated with imminent safety hazards Compliance with the instructions provided is...

Page 8: ... handbook and the appliance The appliance serial number is shown on the rating plate If the handbooks are misplaced new copies may be ordered from the manufacturer or the local dealer When ordering new handbooks always quote the serial number shown on the rating plate ...

Page 9: ... 2 2 Safety instructions in case of malfunctions In the event of faults or incorrect operation close the water and gas supplies and discon nect the appliance from the electrical supply using the main switch Call service 2 3 Disposing of the appliance This appliance is made of recyclable materials and it does not contain any hazardous or toxic substances Dispose of the packing materials and the app...

Page 10: ...18 2 2004 Rev 1 0 Safety 4 ...

Page 11: ...3 215 mm deep containers 3 1 1 Prohibited use Improper use This pasta cooker is not designed for frying The available temperature setting range is insufficient for this operation The manufacturer cannot be held liable for faults due to incorrect installation or inappro priate use of the appliance In these cases the warranty is invalid 3 2 Construction Stainless steel structure supported on 4 heigh...

Page 12: ...appliance is equipped with a safety thermostat if the temperature of the heating ele ments exceeds the limit value when the heating elements are uncovered or if the appli ance is switched on when it is empty of water the power supply will be disconnected automatically and a warning light will illuminate pos 4 fig 1 3 3 1 Operating controls and indicator lights Fig 1 1 Thermostat knob 2 Operation i...

Page 13: ...icator light 2 will switch off Safety thermostat indica tor light 4 will illuminate if the safety thermostat trips This indicator light will switch off when the pasta cooker is switched off and the safety thermostat has been reset as de scribed in the instructions given further ahead in this handbook The various thermostat knob settings are shown in figure 2 Fig 2 1 OFF position 2 70 C position 3 ...

Page 14: ...18 2 2004 Rev 1 0 Functional description 8 ...

Page 15: ...a cooker with hot water If necessary remove any traces of adhesive using non flammable solvents Before using the appliance for the first time clean the tank with hot water and a sponge Clean stainless steel parts with a detergent that does not contain any abrasive substances and is specifically designed for cleaning stainless steel After cleaning the appliance rinse it with clean water and wipe it...

Page 16: ... switch to ON Turning the thermostat knob clockwise will cause the line indicator light to illumi nate pos 3 fig 1 above thereby confirming that the appliance is powered Continue to rotate thermostat knob to start heating the water Heating is provided by immersed armoured heating elements designed to resist mechanical and ther mal stress Operation of the heating system is confirmed by illumination...

Page 17: ...4 2 5 Safety thermostat The appliance is equipped with a safety thermostat The safety thermostat trips if the tem perature of the heating elements increases excessively fire protection function This is a safety feature in the event of malfunctions faulty components or improper use no water in the tank dirty heating elements etc If the safety thermostat trips disconnect power to the appliance and p...

Page 18: ... containing chlorine such as hydrochloric acid or sodium hypochlorite bleach For this reason before using a commercial detergent make sure it will not corrode stainless steel accumulation of ferrous deposits such as those created by rust dissolved in the wa ter in the pipelines especially after the appliance has remained idle for prolonged periods accumulation of ferrous deposits must be avoided a...

Page 19: ...ts to clean the appliance risk of water infiltration resulting in malfunctions and damage Stains and scratches on the stainless steel Scratches and stains can be removed using stainless steel wool pads or synthetic scourers always rub in the same direction as the satin finish Rust If you need to remove rust stains seek advice from industrial cleaner manufacturers to choose a suitable product Indus...

Page 20: ...one service per year 4 3 4 Supplementary cleaning Cooking pasta gives rise to the production of starch of similar properties to egg white that tends to bake on to the heating elements Clean regularly 3 6 times a day according to the frequency with which the appliance is used Turn the thermostat to position 0 Emp ty the tank following the instructions open the drain valve and carefully wipe the hea...

Page 21: ...5 1 1 Installation conditions in compliance with regulatory requirements Note that all appliances installed on premises open to the public must meet the following requirements The appliance must be installed and serviced in compliance with all appli cable regulations and standards namely safety regulations concerning fire and panic hazards in public buildings general regulations valid for all appl...

Page 22: ...materials All packing materials must be disposed of in compliance with the local regulations in force in the place where the appliance is installed Packing materials must be sorted ac cording to their types and delivered to specific collection sites Abide by environmental protection regulations 5 7 Positioning Before performing any work on the appliance close the gas and water supplies and switch ...

Page 23: ... must be rubber insulated and at least equivalent to type H07RN F with conductor cross section commensurate with the maximum power rating of the appliance see Technical specifications table when installing the appliance the upstream mains feeding line must be equipped with an efficient all pole disconnect switch with a contact gap of at least 3 mm The all pole disconnect switch must be located in ...

Page 24: ...ed as follows Disconnect power Remove the protective cover located internally on the right hand side pos 1 fig 6 The power connection terminals are located in the space under the cover Fig 6 1 Protective cover 2 Screws 3 Power connection terminals The connection cable must be secured with the clamp on the appliance to protect the elec trical connections against strain on the cable The earth wire m...

Page 25: ...otential bonding terminal 5 9 Water connection The water connection must be made using a flexible or rigid metal pipe with an adequate diameter 5 10 Drain connection The appliance must be connected to a floor drain The drain connection must be made with a heat resistant at least 90 C plastic pipe The connection to the drainage system must be made in conformity with the local hygiene regulations in...

Page 26: ...ifications table Heat rating see Technical specifications table Natural gas consumption see Technical specifications table Liquid gas consumption see Technical specifications table Connection pressure natural gas G20 see Gas categories and pressures table above liquid gas butane propane G30 G31 see Gas categories and pressures table above city gas G110 G120 see Gas categories and pressures table a...

Page 27: ... on any parts of this appli ance Maintenance must be carried out exclusively by authorized technical personnel PROBLEM POSSIBLE CAUSES ACTION FOR THE USER FOR AUTHORIZED IN STALLERS Water fails to heat No electrical power Check that the appliance is con nected to the power supply Appliance not functioning due to electrical mains circuit Check efficiency of mains con nection heating elements faulty...

Page 28: ...18 2 2004 Rev 1 0 Troubleshooting 22 ...

Page 29: ...18 2 2004 Rev 1 0 Technical specifications 35 8 Technical specifications Connection diagrams 36 Installation and connection drawings 40 Technical specifications table 43 CE conformity declaration 45 ...

Page 30: ...SC00342 Wiring diagram 72 02 CPE 3 N PE 400V 50 60Hz 65 125 C ...

Page 31: ... A046001 X S1 Switch 3 Ph A044650 X B1 Control thermostat 65 125 C 3 Ph A049407 X B16 Safety thermostat 130 C 3 Ph A038506 X E1 Line indicator lamp 400V 150 C A038506 X E11 Operation indicator lamp 400V 150 C A038506 X E6 Safety thermostat indicator lamp 400V 150 C 8218100 X E51 Heating element 7500W 230V ...

Page 32: ...SC00343 Wiring diagram 74 02 CPE 3 N PE 400V 50 60Hz 65 125 C ...

Page 33: ...1 X S1 2 Switch 3F A044650 X B1 2 Control thermostat 65 125 C 3 Ph A049407 X B16 17 Safety thermostat 130 C 3 Ph A038506 X E1 Line indicator lamp 400V 150 C A038506 X E11 12 Operation indicator lamp 400V 150 C A038506 X E6 7 Safety thermostat indicator lamp 400V 150 C 8218100 X E51 52 Heating element 7500W 230V ...

Page 34: ...echnical specifications 40 Installation diagram 72 02CPE Reference B Connection cable entry C Distance between feet D Tank dimensions E Rating plate F Cold water connection G Power connection terminals I Drain connection ...

Page 35: ...ation diagram 74 02CPE 860 354 700 D 42 D 37 296 701 489 B 450 F I 392 305 400 335 I F G G Reference B Connection cable entry C Distance between feet D Tank dimensions E Rating plate F Cold water connections G Power connection terminals I Drain connection ...

Page 36: ...18 2 2004 Rev 1 0 Technical specifications 42 ...

Page 37: ...Tank capacity 72E 26 l Tank capacity 74E 26 26 l Total electric power 72E 7 5 kW Total electric power 74E 15 kW Maximum current 72E A 11 A Maximum current 72E H 19 A Maximum current 74E A 22 A Maximum current 74E H 38 A Minimum lead cross section 72E A 5 x 1 5 mm2 Minimum lead cross section 72E H 4 x 4 mm2 Minimum lead cross section 74E A 5 x 4 mm2 Minimum lead cross section 74E H 4 x 10 mm2 Suppl...

Page 38: ...18 2 2004 Rev 1 0 Technical specifications 44 ...

Page 39: ... Nudelkocher serie 700 New Se declara que el siguiente aparato Cuece pastas eléctricos gama 700 New Mod 72 02CPE 74 02CPE è conforme ai requisiti basilari previsti dalle seguenti direttive CEE is in specification with the fundamental requirements of the following EC directive est conforme aux exigences fondamentales des directives de la Communautè Européenne suivantes entspricht mit den grundlegen...

Page 40: ......

Reviews: