Olis 72/02FRG Installation And Operation Manual Download Page 43

23.3.2005

 Rev.  1.0

Spare parts

39

ID Code Type

Model

Voltage Description

MODULE:Internal parts

200

2591800

G

72G, 74G

Burner nozzle set IT (suitable for two burners)

G

72G, 74G

Nozzle L 130

G

72G, 74G

Nozzle L 210

G

72G, 74G

Nozzle L 230

200

2591801

G

72G, 74G

Burner nozzle set DE (suitable for two burners)

G

72G, 74G

Nozzle  L 115

G

72G, 74G

Nozzle L 210

G

72G, 74G

Nozzle L 230

G

72G, 74G

Nozzle L 245

200

2591810

G

73G

Burner nozzle set IT (suitable for two burners)

G

73G

Nozzle  L 110

G

73G

Nozzle  L 170

G

73G

Nozzle L 185

200

2591811

G

73G

Burner nozzle set DE (suitable for two burners)

G

73G

Nozzle  L 100

G

73G

Nozzle  L 170

G

73G

Nozzle L 185

G

73G

Nozzle  L  195

210

2519430

G

Burner

220

9000610

G

Pipe

230

9000612

G

73G

Pipe

230

9000611

G

72G, 74G

Pipe

240

A016200 G

Nut

250

A016300 G

Ogive

260

A049401 G

Safety thermostat

270

A023020 G

Drain valve

280

8217550

G

Ring

To find out the exact match between nozzles and gas type, refer to chapter 

"Gas technical specifications"

 in

the 

"Installation"

 section

Summary of Contents for 72/02FRG

Page 1: ...GAS DEEP FAT FRYERS 700 Series Models 72 02FRG 73 02FRG 74 02FRG Installation and Operation Manual S N Rev 1 1...

Page 2: ......

Page 3: ...al description 5 3 1 Application of the appliance 5 3 1 1 Prohibited use Use for unintended purposes 5 3 2 Construction 5 3 3 Operating principle 6 4 Operating instructions 7 4 1 Prior to use 7 4 1 1...

Page 4: ...8 Connecting gas supply 17 5 8 1 Checking supply pressure after installation 19 5 8 2 Gas technical specifications 21 5 8 3 Checking operation 23 5 9 Rating plate 23 6 Adjustment instructions 25 6 1 C...

Page 5: ...n this manual should be carried out according to the instructions Have the appliance serviced by a technically qualified person duly authorized by the manufac turer that uses genuine spare parts Failu...

Page 6: ...ance and the manual The rating plate of the appliance shows its serial number If the manuals are missing it is possible to order new ones from the manufacturer or your local representative When or der...

Page 7: ...u should need to add oil while the appliance is in operation use cold oil and pour it into the tank very carefully In this way you will prevent oil from splashing fire hazard In any case do not mix la...

Page 8: ...built by using recyclable raw materials and does not contain any haz ardous or toxic substances To dispose of the appliance and all its packaging materials strictly follow all local regulations in for...

Page 9: ...oses The deep fat fryer is not designed for use as a bain marie or pasta cooker The manufacturer cannot be held liable for any faults caused by defective installation or inappropriate use of the appli...

Page 10: ...be selected between 110 C 230 F and 190 C 374 F item 1 in Fig 1 and intermediate values The easiest way to cook foodstuffs is to fry them in the frying baskets supplied with the appliance The deep fa...

Page 11: ...Remove all packaging materials and adhesive films from the deep fat fryer very carefully Clean the deep fat fryer using hot water Drain cleaning water from the tank see chapter Emptying the tank furth...

Page 12: ...uid deep frying oil only If you should use solid fat to fry melt it in a separate pan before using it to avoid over heating the heat exchanger which could result in a fire hazard During normal operati...

Page 13: ...t flame goes out repeat the lighting process Proper pilot flame lighting can be checked through the viewing hole provided for that pur pose item 4 in Fig 1 further above Fig 3 10 OFF position 11 Pilot...

Page 14: ...or 1 2 maximum load of its full capacity Shake frozen products well before dipping them into the oil Lower the basket into the oil When product is ready lift the basket and hang it from the basket su...

Page 15: ...he appliance when a component breaks down or the fryer is used against the instructions too little oil in the tank using solid fat without melting it first using oil that is dirty and or too old If th...

Page 16: ...h should not be carried out before oil temperature has dropped to 100 C 212 F Empty the tank as follows 1 insert the drain pipe item 15 in Fig 5 into the drain valve and turn the pipe to lock it 2 pla...

Page 17: ...e appli ance with those substances The evaporation of saline solutions over the surfaces of the appliance is particularly harmful to them Routine cleaning Cleaning the appliance thoroughly on a daily...

Page 18: ...ean it and wipe it dry first and then apply a film of a suitable product such as vaseline oil spray or similar products to protect it Turn off the gas shutoff valve fitted upstream of the appliance 4...

Page 19: ...safety regulations on fire hazard and panic in public assembly buildings general regulations applicable to all appliances systems burning combustible gas and liquefied hydrocarbons Then follow the sp...

Page 20: ...C 50 F before switching it on 5 5 Unpacking the appliance Prior to installation remove all packaging materials from the deep fat fryer Some parts are wrapped in adhesive film which should be thorough...

Page 21: ...25 45 Spain Great Britain Ireland Greece II2H3 G20 20 17 25 G30 28 25 35 G31 37 25 45 Italy Italian Switzerland Portugal II2H3 G20 20 17 25 G30 30 25 35 G31 37 25 45 Austria German Switzerland II2H3B...

Page 22: ...egulator and jeopardise its operation Instead interpose a seal gasket suitable for use in gas systems Do not forget to fit a shutoff valve on the gas supply line upstream of the appliance which should...

Page 23: ...e for example a U shaped pressure gauge minimum subdivision 0 1 mbar or a digital pressure gauge Proceed as follows remove the knobs loosen all screws on the guide collars item 22 in Fig 8 remove the...

Page 24: ...pressure if the measured pressure value is within the range shown in Table 1 gas catego ries and pressure values further above the appliance can be started up Other wise contact the gas utility compa...

Page 25: ...0 Town gas consumption m h G110 G120 G20 20mbar Rated pressure mbar 20 Reduced pressure mbar minimum Nozzles 1 100 mm Pilot flame 27 2 27 2 x 2 27 2 x 2 Max 210 x 2 170 x 4 210 x 4 Min Primary air dis...

Page 26: ...0 31 50 mbar Rated pressure mbar 50 Reduced pressure mbar minimum Nozzles 1 100 mm Pilot flame 16 2 16 2 x 2 16 2 x 2 Max 115 x 2 100 x 4 115 x 4 Min Primary air distance mm 5 Table 2 burner specifica...

Page 27: ...rating plate showing the specifications of the corresponding model is applied in the position shown in the installation and connection drawings and includes the data listed below Manufacturer Model s...

Page 28: ...23 3 2005 Rev 1 0 Installation 24...

Page 29: ...ructions 6 1 Converting the appliance to burn a different type of gas To convert for example from natural gas to liquid gas you need to change the nozzles of main and pilot burners the appropriate noz...

Page 30: ...y air adjusting screw 29 Primary air sleeve 2 remove the nozzle item 30 in Fig 14 and replace it with the nozzle shown in Ta ble 2 burner specifications Fig 14 30 Burner nozzle After replacing the noz...

Page 31: ...Adjusting primary air To adjust primary air item 31 in Fig 15 loosen the screw shown in item 32 and move the sleeve until you obtain the values indicated in Table 2 burner specifications Fig 15 31 Pr...

Page 32: ...as you need to replace the nozzle item 35 in Fig 18 with the nozzle shown in Table 2 burner specifications according to the type of gas used You do not need to ad just primary air 1 Remove the drain v...

Page 33: ...by unscrewing the nut shown as item 35 in Fig 18 and using a fixed spanner wrench to counterbalance torsion Fig 18 35 Pilot burner nozzle When nozzle replacement is completed check for proper operati...

Page 34: ...23 3 2005 Rev 1 0 Adjustment instructions 30...

Page 35: ...sure drop in gas supply pipe contact the gas utility company clogged nozzle clean the pilot flame nozzle or re place it see chapter Replacing pi lot burner nozzle in section Adjustment instructions ga...

Page 36: ...afety thermostat trips oil in the tank has dropped below the min imum level top the oil up to the rated level operating thermostat damaged or setting wrong replace the gas valve see chapter Replacing...

Page 37: ...23 3 2005 Rev 1 0 Spare parts 33 8 Spare parts Outer parts 36 Internal parts 38 Pilot flame 40 Valve and stuffing box assembly 42...

Page 38: ...23 3 2005 Rev 1 0 Spare parts 34...

Page 39: ...220 240V 50Hz G 3 N PE 415 240V 50Hz H 3 PE 230V 50Hz I 3 PE 220V 60Hz J 3 PE 380 50Hz K 3 PE 400V 50Hz L 3 PE 415V 50Hz M 3 PE 440V 60Hz N 3 PE 460V 60Hz O 3 PE 480V 60Hz P 1 N PE 220 240V 50Hz R 2 P...

Page 40: ...23 3 2005 Rev 1 0 Spare parts 36...

Page 41: ...1400 G 73G 74G Upper right door hinge 50 2541410 G Upper left door hinge 60 2541390 G Lower left door hinge 70 A044490 G Magnet 80 2599201 G Knob 90 A041105 G Piezoelectric ignition 100 9000337 G 73G...

Page 42: ...23 3 2005 Rev 1 0 Spare parts 38...

Page 43: ...2591810 G 73G Burner nozzle set IT suitable for two burners G 73G Nozzle L 110 G 73G Nozzle L 170 G 73G Nozzle L 185 200 2591811 G 73G Burner nozzle set DE suitable for two burners G 73G Nozzle L 100...

Page 44: ...23 3 2005 Rev 1 0 Spare parts 40...

Page 45: ...PG 330 2510332 G Nozzle 38 1 330 A013230 G Nozzle 27 2 natural gas 340 A016900 G Ogive 350 A017000 G Nut 360 A013302 G Ignition electrode 370 2510698 G Ignition cable 380 A011909 G Thermocouple 390 90...

Page 46: ...23 3 2005 Rev 1 0 Spare parts 42...

Page 47: ...ng box assembly 440 8219900 G Valve 450 A011608 G Pipe fitting 460 A011625 G Ogive 470 A011620 G Pipe fitting 480 A038803 G Washer for packing gland 490 A038801 G Nut 500 A038804 G Metal gasket When r...

Page 48: ...23 3 2005 Rev 1 0 Spare parts 44...

Page 49: ...23 3 2005 Rev 1 0 Technical specifications 45 9 Technical specifications Installation and connection drawings 47 Technical specifications table 50...

Page 50: ...23 3 2005 Rev 1 0 Technical specifications 46...

Page 51: ...23 3 2005 Rev 1 0 Technical specifications 47 Installation drawing 72 02FRG...

Page 52: ...23 3 2005 Rev 1 0 Technical specifications 48 Installation drawing 73 02FRG...

Page 53: ...23 3 2005 Rev 1 0 Technical specifications 49 Installation drawing 74 02FRG A Gas inlet 1 2 ISO 7 1 C Distance between feet D Tank dimensions E Rating plate...

Page 54: ...Difference between minimum and maximum level 72E 72G 74E 74G 2 5 liters Difference between minimum and maximum level 73E 73G 1 liters Baskets dimensions 72E 72G 242x320x120 mm Baskets dimensions 73E...

Page 55: ...005 Rev 1 0 Technical specifications 51 Construction type valid for other countries G A Oil temperature range 110 190 C 230 374 F Table 5 Technical specifications table Item Model Type Voltage Specifi...

Page 56: ...NBG_0700FR_uen11 pdf...

Reviews: