Issue 02 (2019-07-17)
41
BRE-I-5K14K
User Manual
6 System Commissioning
6.2
Powering on the System
Prerequisites
Before turning on the AC switch between the BRE-I-5K14K and the power grid, check
that the AC voltage on the power grid side of the AC switch is within the specified range.
⚫
If the DC is on and the AC is off, the BRE-I-5K14K reports a Grid Failure alarm.
The BRE-I-5K14K can only operate after the fault is rectified.
⚫
The BRE-I-5K14K will automatic recover when it detects the grid recovered. When
the AC is off, the BRE-I-5K14K will shut off from the grid and provide power to
EPS load automatically.
⚫
If the AC is on and the battery is off, the BRE-I-5K14K reports a
Battery Abnormal
alarm.
⚫
If the BRE-I-5K14K is connected to the battery, after turning on the AC switch:
If the DC switch is turned on within 1 minute, the BRE-I-5K14K will run
properly in grid-tied mode.
If the DC switch is not turned on within 1 minute, the BRE-I-5K14K will enter
the nighttime grid-tied mode. Then, after the DC switch is turned on, the BRE-I-
5K14K will shut down and then restart to run in grid-tied mode.
First start
Step 1
Confirm that the battery switch (Figure 5-7) is off.
Step 2
Connect 1#battery pack negative plug (Figure 5-3).
Step 3
Confirm that the Battery ON/OFF button LED (Figure 5-2) is on.
Step 4
Turn on the battery switch
(
Figure 5-7
)
.
Step 5
Start procedure.
Procedure
Step 1
Turn on the AC switch between the BRE-I-5K14K and the power
grid.
Step 2
Turn on the DC switch for PV (Figure 5-7 A).
Step 3
Turn on the DC switch between the PV string and the BRE-I-5K14K
if there is any.
Step 4
Turn on the DC switch at the bottom of the BRE-I-5K14K.
Step 5
Observe the LEDs to check the BRE-I-5K14K operating status.