(SECTION DEDICATED TO THE INSTALLER)
RULES AND REGULATIONS
· Read this manual carefully as it contains important indications and instructions concerning the installation, use, maintenance and
safety of the product.
· This appliance must only be installed and used in a room deemed suitable by the specific authorities and in compliance with the
relevant rules and regulations.
· The technological systems and the installation of the appliance must be done by professional qualified personnel authorised to
release the certificate of conformity and compliance with the regulation in force.
· All the laws, rules and regulations in force concerning civil and industrial buildings must be respected, always using PPE and other
means foreseen by law.
· All laws, rules and regulations concerning the systems, chimney flues, electricity, water, ventilation and aspiration must be respected.
· The manufacturer declines all responsibility arising from incorrect installation, tampering, incorrect use of the
appliance, improper use, poor maintenance, and failure to respect regulations in force.
PRELIMINARY OPERATIONS
· Carefully remove the packing.
· The packing material must be recycled by disposing in the special containers or in the local municipal waste disposal site.
· Before installation, make sure that the appliance is intact, in case of doubt, do not use it and contact the vendor.
· Take the containment grill inside the firebox and position it in the special seats as illustrated in figure 1A.
· Take the smoke discharge collar inside the firebox and place it in the special seat in the upper plate as shown in figure 1B.
POSITIONING THE APPLIANCE
· The place where the appliance is installed must have:
- A floor suitable for supporting a weight greater than that of the appliance. If the existing building is not suitable, appropriate
measures must be taken (e.g. a load distribution plate);
- Flooring suitable for heat dispersion which protects the building against fire risks;
- The installation of the appliance must guarantee easy access for its cleaning, the cleaning of the exhaust gas ducts and the
chimney flue;
- The appliance must be positioned on a horizontal surface;
- A minimum distance from adjacent inflammable material;
- A permanently ventilated room in accordance with the regulations in force.
PROTECTION OF THE FLOOR
· The appliance must rest on a refractory surface. In the case of inflammable flooring (wood, carpet, etc.) prearrange a refractory
base (steel sheet, tiles or similar) with the following size:
- Frontal protrusion
≥
≥≥
≥≥
500 mm;
- Side protrusion
≥
≥≥
≥≥
300 mm;
- Rear protrusion
≥
≥≥
≥≥
100 mm.