INSTALLATION

(SECTION DEDICATED TO THE INSTALLER)

RULES AND REGULATIONS

· Read this manual carefully as it contains important indications and instructions concerning the installation, use, maintenance and

safety of the product.

· This appliance must only be installed and used in a room deemed suitable by the specific authorities and in compliance with the

relevant rules and regulations.

· The technological systems and the installation of the appliance must be done by professional qualified personnel authorised to

release the certificate of conformity and compliance with the regulation in force.

· All the laws, rules and regulations in force concerning civil and industrial buildings must be respected, always using PPE and other

means foreseen by law.

· All laws, rules and regulations concerning the systems, chimney flues, electricity, water, ventilation and aspiration must be respected.

· The manufacturer declines all responsibility arising from incorrect installation, tampering, incorrect use of the

appliance, improper use, poor maintenance, and failure to respect regulations in force.

PRELIMINARY OPERATIONS

· Carefully remove the packing.

· The packing material must be recycled by disposing in the special containers or in the local municipal waste disposal site.

· Before installation, make sure that the appliance is intact, in case of doubt, do not use it and contact the vendor.

· Take the containment grill inside the firebox and position it in the special seats as illustrated in figure 1A.

· Take the smoke discharge collar inside the firebox and place it in the special seat in the upper plate as shown in figure 1B.

POSITIONING THE APPLIANCE

· The place where the appliance is installed must have:

- A floor suitable for supporting a weight greater than that of the appliance. If the existing building is not suitable, appropriate

measures must be taken (e.g. a load distribution plate);

- Flooring suitable for heat dispersion which protects the building against fire risks;

- The installation of the appliance must guarantee easy access for its cleaning, the cleaning of the exhaust gas ducts and the

chimney flue;

- The appliance must be positioned on a horizontal surface;

- A minimum distance from adjacent inflammable material;

- A permanently ventilated room in accordance with the regulations in force.

PROTECTION OF THE FLOOR

· The appliance must rest on a refractory surface. In the case of inflammable flooring (wood, carpet, etc.) prearrange a refractory

base (steel sheet, tiles or similar) with the following size:

- Frontal protrusion 

≥≥

≥≥

 

500 mm;

- Side protrusion 

≥≥

≥≥

 300 mm;

- Rear protrusion 

≥≥

≥≥

 100 mm.

1

1.1

1.2

1.3

1.4

1

1

A

B

Summary of Contents for VIVA

Page 1: ...INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE GB...

Page 2: ...S 2 2 FUEL 2 3 INFORMATIONONFIREWOOD 2 4 STARTINGUP 2 5 LOADINGTHEFUEL 2 6 LIGHTINGANDUSE 2 7 LIGHTINGUP 2 8 LOADINGANDRE LIGHTINGWITHEMBERS 2 9 SHAKINGTHEFIREBOXGRATE 2 10ASH BOX 2 11 ADJUSTMENTS 3 M...

Page 3: ...cial containers or in the local municipal waste disposal site Before installation make sure that the appliance is intact in case of doubt do not use it and contact the vendor Take the containment gril...

Page 4: ...tress heat and the action of the products of the combustion and possible condensation Must be prevalently vertical with deviations of not more than 45 from the axis It must be adequately distanced fro...

Page 5: ...of the combustion products is ensured It must be positioned so that it guarantees an adequate dispersion and dilution of the combustion products and in any case outside the backflow zone where the fo...

Page 6: ...w happens freely through permanent outlets communicating with the outdoors No negative pressure must be caused in the room next to that of the installation as a result of the air sucked out together w...

Page 7: ...t is corrected Do not block the openings or aspiration and heat dispersion slats All repairs or replacements of worn components must only be carried out by a qualified service centre Only use original...

Page 8: ...ctions intermittently and therefore it needs to be fuelled up manually while it is operating Perform the refuelling when the flame is low to avoid any unpleasant spillage of burnt product from the fir...

Page 9: ...n the primary air control to the normal use position as indicated in the ADJUSTMENTS chapter SHAKINGTHEFIREBOXGRATE By acting on the grate shaking pole fig 5 ref B the residual ashes from the combusti...

Page 10: ...a substance suited for these materials Glass tiled parts use a sponge soaked in product suitable for cleaning stove fireplace glass and then wipe with a dry cloth Painted parts use a cloth dampened w...

Page 11: ...ustments and Fuel to be used chapters Reduce the quantity Dry the damp wood before using Check the indications in the Fuel paragraph Call in a chimney sweep Clean Use suitable fuel to light the applia...

Page 12: ...12...

Reviews: