Starting and stopping the operating programs
After having made the settings for the operating programs, they can be used or not, as needed.
Either or both of the programs can be used.
In particular, each time you press the button T11 (Program activation), the situation changes as follows:
Use of Program no. 1 only.
Use of Program no. 2 only.
Use of Programs 1 and 2.
Disuse of both programs..
3.3.16
Resetting all remote control functions
Press the button T10 to reset all the remote control settings.
By doing so all of the settings of the timer are cancelled and the remote control restores all of the default settings.
Furthermore, by pressing button T10, all of the symbols indicated in fig. 28 will appear on the display, thus making it possible to
check the integrity of the display itself.
3.3.17
Managing the unit if the remote control is not available
Should the remote control be lost, the batteries flat or if it is faulty, the appliance may be operated only in automatic mode by pressing
the micro switch positioned underneath the hole located on the console by means of a pointy object.
To switch the air-conditioner off, press the microswitch again.
To restore routing operations in the remote control, you need only issue any command once the remote control is available again.
3.4
ENERGY SAVING ADVICE
-
Always keep the filters clean (see chapter on maintenance and cleaning).
-
Keep the doors and windows closed in the air-conditioned rooms.
-
Keep sunlight out of the room by using curtains, lowering the shades or closing the shutters.
-
Do not obstruct the air flow channels (both inlet and outlet) of the unit; apart from preventing the optimal performance of the
system, this would also jeopardise correct operating and could cause irreparable damage to the unit.
3.5
DIAGNOSIS OF THE PROBLEMS
It is important for the User to distinguish between functional problems and anomalies in relation to the behaviour of the appliance
as foreseen for its normal operation. Furthermore, the most common problems may easily be solved through simple operations
on behalf of the User (See paragraph: Anomalies and solutions), while for all of the other anomalies it is necessary to contact
the Olimpia Splendid Service Centre.
WARNING: Please remember that any attempt to repair the appliance by unauthorised personnel will immediately
invalidate any form of guarantee.
3.5.1
Functional aspects not to be interpreted as problems
-
The compressor does not start up again immediately after a stop (it takes about three minutes to start again).
In the operating logic of the appliance a delay between a compressor stop and its successive restart has been included, so
that the compressor itself is protected against activations that are too frequent.
-
During the heating operation of the heat pump appliances, the flow of hot air may occur some minutes after activation of the
compressor.
Should the fan start at the same time as the compressor, for the first few minutes it would emit cold air into the room (and this
could bother the occupants) since the unit has not yet reached steady running conditions.
3
Downloaded from AC-Manual.com Manuals
Summary of Contents for Unico
Page 3: ...3 UNICO 5 300 mm B A 6 7 8 A 9 Downloaded from AC Manual com Manuals...
Page 4: ...4 15 A 16 10 11 13 14 12 A B Downloaded from AC Manual com Manuals...
Page 5: ...5 UNICO 17 18 B A A 19 N L N L A C B 20 A A D C B 21 Downloaded from AC Manual com Manuals...
Page 6: ...6 A B 25 22 H G LEDD LEDC LEDB LEDA 24 23 A B Downloaded from AC Manual com Manuals...
Page 7: ...7 UNICO 26 A B C B D C A E F B A C 27 Downloaded from AC Manual com Manuals...
Page 89: ...89 UNICO Downloaded from AC Manual com Manuals...
Page 90: ...90 Downloaded from AC Manual com Manuals...
Page 91: ...91 UNICO Downloaded from AC Manual com Manuals...