36
ENGLISH
'HKXPLGL¿FDWLRQRQO\
When used in this mode
the air conditioner eliminates the humidit
\
in the room. This function can be extremel
\
useful bet
Z
een
seasons
particularl
\
on rain
\
da
\
s
Z
hen the temperature is not uncomfortable but the excess humidit
\
feels unpleasant.
In this mode
both room temperature and fan speed settings are ignored
Z
hich correspond to minimum.
As such
no temperature and fan speed indications are displa
\
ed.
Activate this mode b
\
pressing button T4
5XQPRGHVHOHFWRU
until the droplet s
\
mbol D4 and automatic ventilation s
\
mbol D1
are displa
\
ed.
In this operating mode it is normal for the air conditioner to function intermittentl
\
.
3.3.7
Ventilation only
When used in this mode the air conditioner does not perform an
\
action
Z
ith regard to temperature and air humidit
\
in the room.
Activate this mode b
\
pressing button T4
5XQPRGHVHOHFWRU
until the fan s
\
mbol D1 is displa
\
ed.
At this stage
\
ou can select the fan speed (see paragraph 3.3.10).
3.3.8
Well-being function (automatic)
The machine’s temperature is automatically regulated according to the room’s temperature. The fan speed is also auto-
PDWLFDOO\UHJXODWHGDFFRUGLQJWRWKHVHWWHPSHUDWXUHH[FHSWLQGHKXPLGL¿FDWLRQPRGH
Activate this mode b
\
pressing button T4
5XQPRGHVHOHFWRU
until the s
\
mbol D7 is displa
\
ed.
+HDWLQJRQO\PRGHOV¿WWHGZLWKKHDWLQJSXPS
When used in this mode the air conditioner heats the room. This function is onl
\
available on models
Z
ith a heating pump (HP).
Activate this mode b
\
pressing button T4
5XQPRGHVHOHFWRU
until the sun s
\
mbol D2 is displa
\
ed.
In this run mode
the required temperature and fan speed can be set. After three minutes (maximum time) the compressor should
start and the air conditioner starts heating the room. The start of the compressor can be checked through the lighting of the relevant
green LED located on the console.
NOTE: the air conditioner has to defrost its battery periodically. during this operation the air conditioner does not heat
the room, though its internal parts remain on except for the room air fan. when the outdoor temperature is very low, there
may be a slight delay for passage from the minimum to the medium or maximum speed from when the command is sent
to the machine with the remote control.
/LNHGHOD\VPLJKWRFFXURQDFWLYDWLQJWKHVZLQJLQJIXQFWLRQRIWKHPRELOHEDIÀH
$IWHUKDYLQJWXUQHGRIIWKHXQLWWKHLQWHUQDOIDQUXQVVHFRQGVPRUH7KHQLWVWRSVDQGERWKDLUÀDSVFORVH
$LUÀRZGLUHFWLRQFRQWURO
B
\
pressing button T9 it is possible to activate/deactivate the continuous s
Z
ing of the mobile air outlet baf
À
e. When the continual
s
Z
ing is activated
one further press of button T9
Z
ill block the baf
À
e so that the desired vertical direction of the air
À
o
Z
is obtained.
,03257$170RYHPHQWRIWKHPRELOHEDIÀHPXVWQHYHUEHIRUFHGPDQXDOO\
3.3.11
Checking fan speed
Fan speed is checked b
\
button T5. Pressing this button several times
Z
ill change the speed in this order: Lo
Z
Medium
High
and Automatic.
The higher the speed setting
the greater the output of the air conditioner but also the louder its operation. B
\
setting the Automatic
mode
the onboard microprocessor ad
M
usts the automatic speed. The higher the difference bet
Z
een the room temperature detected
and the temperature set
the higher the speed.
As the room temperature nears the setting
fan speed is reduced automaticall
\
.
In dehumidi
¿
cation mode
it is not possible to control the speed as the appliance can onl
\
operate exclusivel
\
at lo
Z
speed.
3.3.12 Night well-being key
Press the T3 button
QLJKWZHOOEHLQJ
to obtain several results
speci
¿
call
\
:
-
Gradual increase of the set cooling temperature.
-
Gradual decrease of the temperature set for heating (onl
\
HP models).
-
Decrease of the unit’s noise level.
-
Savings on night-time consumption of electricit
\
.
In order to activate the Night well-being key press button T3 press after having selected the required operating mode
through button T4 and having set the required temperature through button T7.
Ideally, you should start night well-being mode operation just before you fall asleep.
In cooling
the set temperature is maintained for one hour after activating the night-time comfort button. During the next t
Z
o hours
the setting increases graduall
\
Z
hilst the running of the fan is set to lo
Z
speed. After the second hour
the temperature and fan
speed settings do not change an
\
longer.
In heating mode
the set temperature is held for one hour after starting Night
Z
ell-being mode operation.
During the next t
Z
o hours the setting decreases graduall
\
Z
hilst the running of the fan is set to lo
Z
speed.
3
Summary of Contents for UNICO AIR INVERTER 8 HP
Page 1: ...IR INVERTER...
Page 2: ...2 1 A B C D E F G H 2 4 6 5 7 3 4 3 2 1...
Page 3: ...3 UNICO AIR 5 B A 6 7 8 A 9...
Page 4: ...4 15 10 11 13 14 12 A B...
Page 5: ...5 UNICO AIR 16 17 18 A C B...
Page 6: ...6 21 20 19 H G LED D LED C LED B LED A...
Page 7: ...7 UNICO AIR 22 23 B A...
Page 24: ...3...
Page 40: ...3...
Page 56: ...3...
Page 72: ...3...
Page 88: ...www olimpiasplendid it info olimpiasplendid it 278475B...