3.10 -HEATING MODE (HP ONLY)

a

.  When used in this mode, the appliance heats the room. the air conditioner must be installed in the same 

way as when the appliance runs in cooling mode, with an added water drain pipe at the rear of the air 

conditioner, in place of the cap (24) (see figure 21-22-23).

b

.  if you have no way of continuously draining the water produced by the air conditioner, you can leave the 

rear cap on. in this case, after a certain number of hours of operation (depending on the set temperature, 

humidity level, size of the room etc.) the tanks fills and must be emptied.

c

.  This condition is signalled on the air conditioner’s control panel by the number “3” flashing.

d

.  to restart the air conditioner, proceed as follows:

-  remove the plug from the socket 

-  empty the water tray by removing the rear cap (24)

-  replace the rear cap 

-  plug the air conditioner into the socket

-  press the stand-by key (SW7 or B1) to restart the air conditioner

e

.  Heating mode can be selected by pressing key B2 on the remote control or SW6 on the control panel until 

the heating only symbol (

S1

S2

S3

S4

S5

S6

S7

S8

S13

S14

S15

S12

S9

S10

S11

D1

D2

D3

Blue Air   Turbo

) appears on the remote control and on the control panel display. 

f. 

the internal fan always switches on at minimum speed and after a few seconds goes to the selected 

speed (by pressing B6 or SW2) or to Blue air automatic speed. 

g

.  the set temperature can be adjusted between 16 °C and 27 °C (60 f and 81 f where applicable) with 1 

°C variations by pressing keys B4/B5 or SW4/SW5. 

  the relative temperature appears on the remote control and on the control panel display (d1, d2, d3.). 

h

. When this operating mode is activated, if the ambient temperature is below that set, the air conditioner 

will switch on and supply heat after a few minutes. 

i

.  on reaching the set temperature, the air conditioner will switch off until the ambient temperature has once 

again dropped below that selected.

 

 

Both of these conditions are entirely normal and must not be considered as mal-

functions.

 

•  If the ambient temperature is particularly low, the appliance is periodically de-

activated for a few minutes.

 

•  In the event of particular environmental conditions, the external fan may be 

cyclically deactivated.

3.11 - TURBO FUNCTIONING 

a

.  this mode can be selected by pressing B2 on the remote control or SW6 on the control panel until symbol 

turBo appears on the control panel display. 

b

. it sets the unit in cooling mode with Set temperature =16°C and maximum fan speed to reach the set 

temperature as quickly as possible.

Summary of Contents for SILENT 10 P

Page 1: ...ISTRUZIONI PER INSTALLAZIONE USO E MANUTENZIONE Caution risk of fire Attenzione rischio di incendio AIR PRO IT EN LOCAL AIR CONDITIONER INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE CONDIZIONATORE...

Page 2: ......

Page 3: ...manutenzione sull apparecchio 7 Per il corretto funzionamento dell apparecchio rispettare le distanze minime e le indicazioni riportate nel presente manuale vedere figura 1 8 Per il corretto collegam...

Page 4: ...6 SILENT 5 2 1 7 8 9 min 30cm m in 20cm 20 20 min 70cm 1 3 5 2 4...

Page 5: ...min 2m min 2m 1 26 1 2 2 2 2 6 8 8a 7 9 9a 8 8 10...

Page 6: ...16 23 8m 23 17 19 18 20 OK NO 22a 24 23 24 22...

Page 7: ...USE OF THE APPLIANCE 20 3 1 CONTROL PANEL SYMBOLS AND KEYS Fig B 21 3 2 REMOTE CONTROL KEYS Fig C 22 3 3 USE OF THE REMOTE CONTROL 23 3 3 a Insertion of batteries 23 3 3 b Replacement of batteries 23...

Page 8: ...d from your local town hall your refuse collection service or in the store at which you bought the product This regulation is valid only in EU member states 3 13 RESETTING ALL THE REMOTE CONTROL FUNCT...

Page 9: ...hs marked with this symbol contain very important information and recommendations particularly as regards safety Failure to comply with them may result in danger of injury to the operators loss of the...

Page 10: ...esents the risk of burns due to contact with components at very high temperatures Do not cover Indicates to the personnel concerned that it is prohibited to cover the appliance to prevent over heating...

Page 11: ...the manual carefully for future reference 4 After removing the packaging check that the appliance is in perfect condition The packaging materials must not be left within reach of children as they can...

Page 12: ...disconnect the plug from the power socket For repair work contact solely the technical service centres authorised by the manufacturer and ask for original spare parts to be used Failure to do this can...

Page 13: ...a stable plane and levelled surface 31 Leave at least 30cm of free space on both sides and 20cm behind the appliance and leave at least 30cm of free space above it Fig 1 32 Do not place the appliance...

Page 14: ...functioning or faults if the cord or plug are damaged or if it has been dropped or damaged in any manner Turn the appliance off disconnect the plug from the socket and let it be checked by professiona...

Page 15: ...very humid environments laundries greenhouses etc or in places with other machines that generate a strong heat source in proximity of a sources of salt water or sulphurous water DO NOT use gas gasolin...

Page 16: ...ance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater 6 Do not pierce or burn 7 Be aware tha...

Page 17: ...liances The storage of equipment should be in accordance with the manufacturer s instructions 21 Storage of packed unsold equipment Storage package protection should be constructed such that mechanica...

Page 18: ...be displayed g Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work A degree of ventilation shall continu...

Page 19: ...components the casing is not altered in such a way that the level of protection is affected This shall include damage to cables excessive number of connections terminals not made to original specific...

Page 20: ...ed from the system or isolated by means of shut off valves in a part of the system remote from the leak Oxygen free nitrogen OFN shall then be purged through the system both before and during the braz...

Page 21: ...rior to re use of reclaimed refrigerant It is essential that electrical power is available before the task is commenced a Become familiar with the equipment and its operation b Isolate system electric...

Page 22: ...er with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants In addition a set of calibrated weighing scales shall be availab...

Page 23: ...it 1 1 5 m flexible pipe 2 Window air conveyor outlet 5 Window suction cup 6 Use and maintenance manual 7 Remote control 8 SLIDERforinstallationonsliding rollerwindow 9 Condensation discharge pipe deh...

Page 24: ...ded to check that the wheels are clean and that they can move freely 2 2 WARNINGS A failure to respect what follows may cause damages to the appliance a Install the air conditioner on flat and stable...

Page 25: ...d as shown in figures 8 and 8a f Position the SLIDER 8 and adapt it Fig 8a g Position the flexible hose 1 Fig 8a Extend the pipe only to the necessary extent so that the air conveyor remains closed be...

Page 26: ...Remove the cap 24 b Insert a pipe 9 in the connector Make sure the end of the discharge pipe 9 is positioned on a drain well or in a container Make sure the pipe 9 is not clogged 3 USE OF THE APPLIAN...

Page 27: ...ation Dehumidification Heating model HP only SW7 On off Stand by appliance D1 Set temperature or TIMER delay time D2 Set temperature or TIMER delay time D3 Set temperature or TIMER delay time S1 Heati...

Page 28: ...ime B5 DecreasedesiredtemperatureorTIMERdelay time B6 Select ventilation speed maximum speed medium speed minimum speed maximum speed B7 Select BLUE AIR fan speed B8 Set appliance switch on delay TIME...

Page 29: ...ay also interfere with transmissions between remote control and air conditioner Remove the batteries in case of prolonged disuse of the remote control 3 3 a Insertion of batteries To insert the batter...

Page 30: ...e curtains walls etc between the remote control and the appliance reduces the remote control range 3 4 USE OF THE APPLIANCE Work as follows in order to use the appliance To prevent possible damages to...

Page 31: ...the relevant B6 or SW6 key 6 symbol on the remote control Here are the details about the available fan speeds Symbols displayed High FAN Med FAN Min FAN 3 6 COOLING MODE COOL a In this mode the appli...

Page 32: ...m ventilation speed the external fan speed is also reduced resulting in a considerably quieter running appliance With particularly low ambient temperatures the external fan speed is always forced to m...

Page 33: ...the remote control and on the control panel display f The internal fan always switches on at minimum speed and after a few seconds goes to the selected speed by pressing B6 or SW2 or to BLUE AIR auto...

Page 34: ...irm the desired delay time by pressing B10 The remote controller display shows the delay countdown to the switch ON operation d When the delay time set has elapsed the unit switches ON with latest sel...

Page 35: ...after which the unit will switch OFF starting from timer confirmation c If no button is pressed within 5 seconds the timer setting function will terminate automatically Confirm the desired delay time...

Page 36: ...et damaged by use or excessive dirt We recommend tat you check they are always clean and free to move ertanto di verificare che le ruote risultino pulite e libere nel loro movimento 3 17 AUTORESTART I...

Page 37: ...23 with a water jet aimed at the side opposite the accumulation of dust c If the dirt is particularly difficult to remove such as grease or other types of deposit first immerge the filter in a soluti...

Page 38: ...tioner b Check that the air outlet or inlet are not obstructed especially after a long period of inactivity of the air conditioner 4 2 a Discharging condensation When condensation in the lower tray re...

Page 39: ...appliance If the inconvenience persists and the error code doesn t turn off electrically disconnect the appliance and refer to an Assistance Centre 5 TECHNICAL DATA For the technical data please cons...

Page 40: ...ving the conditioner Clean the filter Switch the appliance back on and press button SW7 on the control panel for 5 seconds so that the alarm signal disappears from the display Call the Service Centre...

Page 41: ...MBOLI E TASTI PANNELLO COMANDI Fig B 21 3 2 TASTI TELECOMANDO Fig C 22 3 3 USO DEL TELECOMANDO 23 3 3 a Inserimento delle batterie 23 3 3 b Sostituzione delle batterie 23 3 3 c Posizione del telecoman...

Page 42: ...tto contattare l ufficio comunale il servizio locale di smaltimento rifiuti o il negozio in qui stato acquistato il prodotto Questa disposizione valida solamente negli stati membri dell UE 3 13 RESETT...

Page 43: ...CNICA CLIENTI Indice I paragrafi preceduti da questo simbolo contengono informazioni e prescrizioni molto importanti particolarmente per quanto riguarda la sicurezza Il mancato rispetto pu comportare...

Page 44: ...schio di subire bruciature per contatto con componenti con elevata temperatura Non coprire Segnala al personale interessato che vietato coprire l apparecchio per evitarne il surriscaldamento Attenzion...

Page 45: ...teriore consultazione 4 Dopo aver tolto l imballaggio assicurarsi dell integrit dell apparecchio gli elementi dell imballaggio non devono essere lasciati alla portata dei bambini in quanto potenziali...

Page 46: ...a di corrente Perl eventualeriparazionerivolgersiesclusivamenteaicentridiassistenzatecnica autorizzati dal costruttore e richiedere l utilizzo di ricambi originali Il mancato rispetto di quanto sopra...

Page 47: ...stabile piana e livellata 31 Lasciare almeno 30cm di spazio libero sui lati e 20cm dietro l apparecchio e lasciare almeno 30cm di spazio libero sopra l apparecchio Fig 1 32 Non collocare l apparecchio...

Page 48: ...in qualsiasi modo Spegnere l apparecchio scollegare la spina dalla presa di corrente e farlo controllare da personale professionalmente qualificato 49 Non smontare n apportare modifiche all apparecch...

Page 49: ...vanderie serre ecc o in locali dove sono presenti altri macchinari che generano una forte fonte di calore in prossimit di una fonte di acqua salata o acqua sulfurea NON usare gas benzine o altri liqui...

Page 50: ...a sull apparecchio 5 L apparecchio deve essere immagazzinato in un locale sen za la presenza di fonti di accensione a funzionamento con tinuo per esempio fiamme libere apparecchi funzionanti a gas o r...

Page 51: ...arecchiatura dispositivi Lo stoccaggio dell apparecchiatura deve essere conforme alle istruzioni del co struttore 21 stoccaggio di apparecchiatura imballata invenduta L imballo deve essere costruito i...

Page 52: ...per assicurarsi che non esistano elementi infiammabili o rischi di ignizione Utilizzare segnaletica antifumo g Area ventilata Assicurarsi che l area di installazione sia all aperto o adeguatamente ve...

Page 53: ...ttrezzaturadurantelariparazione un dispositivo di rilevamento perdite permanentemente funzionante deve essere posizionato nel punto pi critico per avvisare l operatore di una situazione potenzialmente...

Page 54: ...rigerante e corrodere le tubazioni in rame Se si sospetta una perdita tutte le fiamme libere devono essere rimosse spente Se viene rilevata una perdita di refrigerante la quale necessita di saldatura...

Page 55: ...enti E considerata buona prassi recuperare tutti i refrigeranti in maniera sicura Prima di eseguire questa operazione prendere un campione di olio e di refrigerante nel caso sia necessaria un analisi...

Page 56: ...valvole d intercettazione perfettamente funzionanti I cilindri di recupero vuoti devono essere messi sotto vuoto e se possibile raffreddati prima del recupero L attrezzatura di recupero deve essere pe...

Page 57: ...5 m 2 Convogliatore terminale per finestra 5 Ventosa per finestra 6 Manuale di uso e manutenzione 7 Telecomando 8 SLIDERperinstallazioneafinestrascorrevole tapparella 9 Tubo scarico condensa modalit...

Page 58: ...raccomanda di verificare che le ruote risultino pulite e libere nel loro movi mento 2 2 AVVERTENZE La mancata osservanza di quanto segue pu essere causa di danni all apparec chio a Installare il clima...

Page 59: ...8 e adattarlo Fig 8a g Posizionare il tubo flessibile 1 Fig 8a Estendere il tubo solo per il necessario in modo che il convogliatore dell aria rimanga chiuso tra i battenti dell infisso Fig 10 2 4 CO...

Page 60: ...4 b Inserire un tubo 9 sul raccordo Assicurarsi che la parte terminale del tubo di scarico 9 sia posizionata su un pozzetto di scarico o in un recipiente Assicurarsicheiltubo 9 nonsiaostruito 3 USO DE...

Page 61: ...Deumidificazione Riscaldamento solo modello HP SW7 Accensione spegnimento Stand by dell apparecchio D1 Temperatura impostata o tempo di ritardo TIMER D2 Temperatura impostata o tempo di ritardo TIMER...

Page 62: ...ura 2 Impostazione ritardo 3 Spegnimento programmato 4 Trasmissione telecomando 5 Modalit Auto fan 6 Velocit ventilatore Modalit ventilatore 7 Modalit notturna 8 Accensione programmata B1 Accensione s...

Page 63: ...ti possono interferire nelle trasmissioni tra telecomando e condizionatore Estrarre le batterie di alimentazione nel caso di inutilizzo prolungato del telecomando 3 3 a Inserimento delle batterie Per...

Page 64: ...ecc tra il telecomando e l apparecchio riduce la portata del telecomando 3 4 UTILIZZO DELL APPARECCHIO Per utilizzare l apparecchio operare come segue Per prevenire eventuali danni al compressore ogn...

Page 65: ...imbolo 6 sul telecomando Queste sono le velocit possibili per il ventilatore Simboli visualizzati Velocit MASSIMA Velocit MEDIA Velocit MINIMA 3 6 MODALIT RAFFREDDAMENTO COOL a Usando questa modalit l...

Page 66: ...ene diminuita anche la velocit del ventilatore esterno con conseguente sensibile riduzione della rumorosit complessiva dell apparecchio Contemperatureambienteparticolarmentebasselavelocit delventilato...

Page 67: ...are sia sul telecomando sia sul display del pannello di controllo f Il ventilatore interno si accende sempre alla minima velocit e dopo alcuni secondi si porta alla velocit selezionata premendo B6 opp...

Page 68: ...er terminer auto maticamente Confermare il valore desiderato premendo B10 Il display del telecomando mostra il conto alla rovescia per l accensione d Una volta trascorso il tempo impostato l unit si a...

Page 69: ...lla conferma del timer c Se non viene premuto alcun tasto entro 5 secondi la funzione di impostazione del timer terminer auto maticamente Confermare il valore desiderato premendo SW3 d Per annullare l...

Page 70: ...ssono essere danneggiate dall uso o essere sporche Si consiglia di verificare che le ruote risultino pulite e libere nel loro movimento 3 17 AUTORESTART In caso di interruzione dell alimentazione elet...

Page 71: ...mite un getto d acqua rivolto nella direzione opposta a quella di accumulo della polvere c Nel caso di sporco particolarmente difficile da togliere come unto o incrostazioni di altro tipo necessario i...

Page 72: ...o l ingresso dell aria non siano ostruiti soprattutto dopo un lungo periodo di inat tivit del condizionatore 4 2 a Scarico acqua di condensa Quando l acqua di condensa presente nel vassoio inferiore...

Page 73: ...nella presa di corrente d riavviare l apparecchio Se l inconveniente persiste e il codice di errore non si spegne scollegare elettricamente l ap parecchio e rivolgersi ad un Centro di Assistenza 5 DAT...

Page 74: ...o allarme troppo frequente chiamare il Centro Assisten za HP questo allarme normale in caso di funzionamento in riscaldamento con in stallazione senza tubo di scarico acqua Il comportamento del climat...

Page 75: ......

Page 76: ...d or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure If you have any queries regarding your product or its warranty please find contacts below...

Reviews: