2.3 - MOBILE INSTALLATION
the air conditioner must be installed in a suitable environment.
it is recommended to reduce solar radiation through curtains, Venetian blinds and to keep doors and windows
closed.
a.
Position the air conditioner in front of a window or french window.
b.
Insert the flexible hose (1) terminal on the air outlet grid of the appliance (26) as shown in figure 8.
c.
Fold the conveyor (2) end back on itself and insert it into the flexible hose (1) (fig.9).
d.
Position the terminal (2) in such a way as to make air exit to the exterior (fig.9a)
e.
If you possess a sliding window (vertical or horizontal) or a shutter, it is possible to use the supplied
SLIDER (8) which allows a more efficient installation.
For the installation with SLIDER (8), proceed as shown in figures 8 and 8a.
f.
Position the Slider (8) and adapt it (fig.8a)
g.
Position the flexible hose (1) (Fig.8a)
Extend the pipe only to the necessary extent, so that the air conveyor remains closed between
the fixture shutters (Fig.10).
2.4 - ELECTRICAL CONNECTION
The appliance is fitted with a power cable with plug.
Before connecting the air conditioner ensure that:
• The voltage and power frequency values match those specified on the
appliance plate data.
• The power line is equipped with an effective earth connection and is
correctly sized for maximum power consumption of the air conditioner.
• The appliance’s power network must be equipped with a suitable
omnipolar disconnection device compliant with national installation
regulations.
• The appliance is powered solely through a socket compatible with the plug provided.
CAUTION
Any replacement of the power cable must be carried out solely by Olimpia Splen-
did technical support or by similarly qualified personnel.