UPPER WALL CONFIGURATION DETERMINES AN AUTOMATIC CORRECTION OF THE ROOM
TEMPERATURE EQUAL TO 43°F IN HEATING MODE.
2.6 - ENERGY BOOST/SYSTEM ENABLE CONTACT INPUT
the input located on the terminal (Y2) of the main board (Y1) can be used to activate the functions
ENERGY
BOOST
or
SYSTEM ENABLE
of the air conditioner (fig. 46).
Configuration and use of the input
ENERGY BOOST
or
SYSTEM ENABLE
:
a
. insert the plug in the power socket to power the air conditioner, then make sure the latter is switched to
stand-by mode.
b
. on the control panel, press the key
MODE
for more than 10 seconds until an acoustic signal is emitted.
c
. the display shows the parameter
P0
.
d
. release the key
MODE
and press it again until you select the parameter
PI
.
e
. release the key
MODE
and press it again for 2 seconds.
f
. Press keys
+
or
-
to select the desired configuration.
g
. With value
PI = 0
, the input works from
SYSTEM ENABLE
.
When the contact opens, the air conditioner is forced in stand-by mode.
When the contact closes, the air conditioner restores its previous operation condition.
h
. With value
PI ≠ 0
, the input works from
ENERGY BOOST
.
When the contact opens, the display shows the code
E
, desired temperature is reduced by
PI
°C if the
air conditioner is in cooling mode or increased by
PI
°C if the air conditioner is in heating mode.
When the contact closes, the air conditioner restores its previous operation condition
the input
ENERGY BOOST
has no effect when the air conditioner is in fan, dehumidifier or automatic
modes.
• This operation must be performed only by the installer or any similarly qual-
ified personnel and in compliance to the current national regulations.
• To prevent the risk of an electric shock it is mandatory to switch off the main
switch before performing the electrical connections or any maintenance op-
eration to the appliances.
to set the appliance to activate one of the two functions, proceed as follows:
a
. Raise the air suction grille (3) and remove the two screws (3a) (fig. 28).
b
. Extract the right (release using a screwdriver) and left (1a) doors of the front cover, then rotate the flap
(1) and remove the three screws (1b) (fig. 29).
c
. Remove the front cover (fig.30).
d
.
Unscrew the two fixing screws (X2) to remove the front cover of the switchgear (X1) (fig. 31).
e
. Remove the supplied jumper (Y3) from the screw terminal (Y2) (fig. 47).
f
. Close the switchgear.
g
. reassemble the front cover of the machine.
the input must be piloted by a potential-free dry contact.
Do not use a cable longer than 10 meters.
Summary of Contents for maeStro Pro
Page 1: ...INVERTER EN INSTRUCTION FOR USE AND MAINTENANCE...
Page 5: ...M Y 4 5 3...
Page 6: ...min 300mm 11 8 8 9 B N 8mm 0 3 6 H H 7 6...
Page 7: ...202 mm G 162 mm 130 mm G 8 6 4 5 1 10 12 11 G F D F G 13 14...
Page 8: ...6mm 0 24 15 19 17 16 20 18 F E E E...
Page 9: ...22 23 A A B B 21 W...
Page 10: ...H H L L 26 28 24 29 25 L L 27 3 3 3a 3a 1 1 1a 1a 1a 1b 1b 1b 1a A A A A A 1c...
Page 11: ...34 32 33 35 J1 J2 J1 J2 X3 X4 30 31 X1 X2 X2...
Page 12: ...min 80mm 3 2 41 39 40 F 3 F F2 F1 F F2 F2 F1 F1 8m 315 38 36 37 10 7...
Page 13: ...43 3 3 42 F 44 45 6 6a min 5 L 1 3 gal...
Page 14: ...46 47 Y2 Y2 Y3 Y3 Y1...
Page 47: ...261725A...