11
MAESTRO PRO INVERTER
–
Release the MODE key and press it again until parameter Pl is
selected.
–
Release the MODE key and press it again for 2 seconds.
–
Press the + or - keys to select the desired configuration.
–
With PI value = 0, the input works as a SYSTEM ENABLE.
When the contact opens, the air conditioner is forced into
stand-by mode. When the contact closes, the air conditioner
restores
the previous operating state.
–
With PI value ≠ 0, the input works as ENERGY BOOST. When
the contact opens, the display shows code E, the desired
temperature is reduced by PI
°C if the air conditioner is in
cooling mode, or increased by PI °C if the air conditioner is in
heating mode. When the contact closes, the air conditioner
restores the previous operating state. The ENERGY BOOST
input has no effect when the
unit
is in
fan only
,
dehumidifier or
automatic mode
.
2.5.5.1 System ENABLE
Contact WINDOW
Contact open: unit in stand-by, cannot be activated by remote
control or by touch keyboard.
Contact closed: the unit is ready and can be activated.
Contact closed: when the contact closes, the
unit
restores the
previous operating condition
.
2.5.5.2 Energy BOOST
Remote setpoint increase / decrease
Contact open: regular set point set by remote control or
keyboard.
Contact closed: the set point is increased in heating and reduced
in cooling by a certain offset that can be set by parameter
.