b.
Individual connect the power cord and signal line, adjust the dial switch (fig. 13).
J1
- The wire holder of power cord(three-position)
J2
- The wire holder of signal line (five-position)
J3
- Display cover plate
J4
- Dial switch
5.1 - Terminal Board Diagram
Please refer to the board diagram for the wiring. (Fig.F)
NOTE:
The heat convectors can be connected to the Central Control Monitor, CCM. Before commissioning the
unit, perform the wiring correctly and set the system address and the network address.
Single phase appliance
POWER SUPPLY
PHASE
Single-phase
FREQUENCY AND VOLTAGE
220-240 V~ 50 Hz
SWITCH/FUSE (A)
15/15
APPLIANCE
WIRING (mm
2
)
and EARTH (mm
2
)
UP TO 20 M
Twisted pair 2.5 mm
2
UP TO 50 M
Twisted pair 6 mm
2
The power cord type designation is H05RN-F or above.
Please adopt the shielded twisted-pair wire, and connect the shielded layer to E
The reserved wire control function is indicated in broken line table, users can purchase the wire controller
when necessary.
5.2 - NETWORK ADDRESS SET
Every appliance connected to the network has a unique network address that distinguishes it from the others.
Address code of air-conditioner in LAN is set by code switch on Network Interface Module (NIM), and the
set range is 0-63
(see figure 14).
ALIMENTAZIONE UNITÁ
220-240V~ 50Hz
Al monitor
di controllo centrale
(CCM) COMM. BUS
All’interruttore
ON/OFF
Alla scatola
di comando
R = Rosso
B = Nero
R = Rosso - W = Bianco - A = Blu
X = Pannello display
Z = Scatola di comando