Olympia Electronics S.A
.
5.6-6.6V DC
1W
0205183
NOTE:
LED= Light Emitting Diode
LABELING EXPLANATION:
X:
Self contained
0:
Non maintained
(*)
A:
Including test device
*90:
1.5 hour duration
180:
3 hours duration
(*)
Non Maintained operation: The luminaire lights its illumination source,
only in power
supply’s failure.
Maintained operation: The luminaire lights its illumination source, when it is powered by the
923473000_0
9
_00
1
fixed connection between main pcb and led module
55 °C max. across the board
LED MODULE CHARACTERISTICS
Manufacturer
Model Number
Voltage Range
Connections
Nominal Power
Temperature (tc)
TEST
A-1900
Manual TEST with the A-1900 Test card (not included
and is available only on request).
In order to test the
device you must place the card in front of the indications
TEST mark and remove it instantly for TEST.
GR-47
0
/WP
GR-471/WP
GR-472/WP
GR-473/WP
CAUTION
:
Do not view directly with bare eyes
Battery replacement
It can be done only by a competent person and after the mains interruption
.
3
. Disconnect the connector and remove the old battery.
4
. Connect the new battery with the same type (step
2
of the installation
instructions
) and place it in
the position of the old one.
5
.
Replace the removed parts
and power the device.
1
.
Detach the front cover by applying pressure using a flat blade screw driver. Next, unfasten the four
retaining screws without removing them and remove the diffusor.
The light source contained in this luminaire shall only be replaced by the manufacturer, or his
agent, or a similar qualified person.
NOTE! The light source is non-user replaceable.