27
PROBLEM
CAUSE
SOLUTION
Pressing the main switch
(1) to position
”I”
, the
motor buzzes, but does
not start.
Unsuitable electrical system and/
or extension lead
Check the instructions for connecting
up to the mains power supply have
been followed correctly (refer to the
INSTRUCTIONS MANUAL – SAFETY
INSTRUCTIONS
), especially as regards the
use of an extension lead.
The cleaner does not
deliver hot water
There is not enough fuel in the
tank.
Top up with fuel.
The fuel filter is dirty.
F o l l o w t h e i n s t r u c t i o n s i n
“SUPPLEMENTARY MAINTENANCE”.
The boiler’s safety thermostat has
tripped.
Leave the cleaner to cool down for a few
minutes so the safety device can reset.
SHOULD IT TRIP AGAIN, DO NOT USE THE
CLEANER AND CONTACT A QUALIFIED
TECHNICIAN.