User Manual LR-1BS2
OMEN-1BS2-202202
14
Appendix B Example for electrical connection
INPUT:
Figure 11 INPUT
Input and GND connection is valid.
The input signal is isolated by optocoupler, which is much safer.
Power supply could be identical to IO power supply or different from it
Note:When the Input is not connected:
Bank 0 is activated if VDDIO is not connected
Bank 15
is activated if VDDIO
is connected to the power supply
OUTPUT:
Figure 12 OUTPUT
The outputs use push-pull circuits and support both PNP and NPN modes
High level output is effective.
The output signal is isolated by optocoupler, which is much safer