- 26 -
Note
:
The instrument is initialised to detect only
one type of gas (toxic or oxygen).
The "detected" gas is programmed in the factory and engraved on a label [sticked
on TX/) housing].
3
3
.
.
S
S
W
W
I
I
T
T
C
C
H
H
I
I
N
N
G
G
O
O
F
F
F
F
1
1
Keep the "OFF" key pressed
The display then indicates the following countdown:
and goes out (with confirmation beep).
Then release the key.
4
4
.
.
I
I
L
L
L
L
U
U
M
M
I
I
N
N
A
A
T
T
I
I
O
O
N
N
In order to read the measurement in dark locations it is possible to illuminate the
display by momentarily pressing the following key :
2 red light-emitting diodes placed on either side of the display provide this
illumination for 10 seconds (as standard).
1
We can remove only in factory the « OFF » function if you need (special version).
All parameter existing when the instrument operates will be when dry batteries are replacing
-2-
-1-
-0-
ENTER