Mechanical Specifications
Dimensions :
OLCT 700
7"H x 2.2" Dia.; 178mmH x 65mm Dia.
OLCT 710
13.74"H x 5.0"W x 5.12"D; 349mmH x 127mmW x 130mmD
Weight:
2.5 lbs; 1.14 kg (OLCT 700 only)
7.4 lbs; 3.36 kg (OLCT 710 w/aluminum j-box)
16.4 lbs; 7.44 kg (OLCT 710 w/stainless steel j-box)
Electrical Specifications
Input Voltage:
11-30 VDC
Power Consumption:
Normal operation = 68mA (<1.7 watt)
Maximum = 85mA (2 watts)
Inrush current:
1.0A @ 24V
RFI/EMI Protection:
Complies with EN 50270:06 for Type 2 device
Cable Requirements:
Power/Analog:
3-wire shielded cable
Maximum distance is 4000 meters with 14 AWG
Serial Output:
2-wire twisted-pair shielded cable specified for RS-485 use
Maximum distance is 1200 meters to last detector
I/O Protection:
Over-Voltage, Miss-wiring, EMI/RFI Immunity