OLCT 700/710 TP
Page 20 of 45
Rev. C.1
OLCT 700/710 TP Instruction Manual
Set Range
Set Serial ID
Set Heater Power
Signal Output Check
Restore Default Settings
3.5.1
Navigating Program Mode
From Normal Operation, enter Program Mode by holding the magnet over PGM2 for 4 seconds (until the
displays starts to scroll “View Sensor Status”). Note, the “◄” prompt will show that the magnetic switch is
activated during the 4 second hold period. The OLCT 700/710 will enter Program Mode and the display
will display the first menu item “View Sensor Status”. To advance to the next menu item, hold the magnet
over PGM1 or PGM2 while the current menu item’s text is scrolling. At the conclusion of the text scroll
the arrow prompt (“◄” for PGM2 or “
►
” for PGM1) will appear, immediately remove the magnet. The
OLCT 700/710 will advance to the next menu item. Repeat this process until the desired menu item is
displayed. Note, PGM1 moves the menu items from right to left and PGM2 moves the menu items from
left to right.
To enter a menu item, hold the magnet over PGM1 or PGM2 while the menu item is scrolling. At the
conclusion of the text scroll the “◄” (or “
►
”) prompt will appear, continue to hold the magnet over
PGM1 or PGM2 for an additional 3-4 seconds to enter the selected menu item. If there is no magnet
activity while the menu item text is scrolling (typically 4 repeated text scrolls), the OLCT 700/710 will
automatically revert to Normal Operation.
3.5.2
View Sensor Status
View Sensor Status
displays all current configuration and operational parameters including: sensor type,
software version number, detection range, AutoSpan level, days since last AutoSpan, estimated remaining
sensor life, heater power, heater voltage, raw resistance, mA output, input voltage and detector ambient
temperature.
From the
View Sensor Status
text scroll, hold the magnet over PGM1 or PGM2 until the “◄” prompt
appears and continue to hold the magnet in place for an additional 3-4 seconds (until the display starts to
scroll “Status Is”). The display will scroll the complete list of detector status parameters sequentially:
Sensor Model Type
The menu item appears as: “700 TP”
Current Software Version
The menu item appears as: “V X.XXZ”
Range of Detection
The menu item appears as: “Range XXXppm”
Serial ID address
The menu item appears as: “Serial ID XX”
AutoSpan Level
The menu item appears as: “Auto Span Level XXppm”
Days Since Last AutoSpan
The menu items appears as: “Last Cal XX days”
Remaining Sensor Life
The menu item appears as: “Sensor Life 100%”
Sensor Heater Power
The menu item appears as: “Heater XXXmW”
Sensor Heater Voltage
The menu item appears as: “Heater X.XXVDC
Summary of Contents for 700 TP Series
Page 6: ...OLCT 700 710 TP vi OLCT 700 710 TP This page has been left blank intentionally...
Page 20: ...OLCT 700 710 TP Page 14 of 45 Rev C 1 OLCT 700 710 TP Instruction Manual...
Page 46: ...OLCT 700 710 TP Page 40 of 45 Rev C 1 OLCT 700 710 TP Instruction Manual...
Page 48: ...OLCT 700 710 TP Page 42 of 45 Rev C 1 OLCT 700 710 TP Instruction Manual...