NOTICE
:
In order to be able to service this appliance, it must
be installed with the casters supplied, a connector complying
with
ANSI
22
7
.69
CSA
6.7
6
and a quick-disconnect device
complying with
ANSI 227.47 CSA
6.9.
It must also be installed
with restraining means to guard against transmission of strain
to the connector as specified in the appliance manufacturer’s
instructions.
INSTALLATION GUIDELINES
GAS
Gas installation must conform with local codes, or in the absence of local codes, with the
National
Fuel Cas Code, ANSI 2223.1 /NFPA 54,
or the
Natural Gas and Propane Installation Code,
CSA B749.1
ELECTRICAL INSTALLATION
This appliance, when installed, must be electrically grounded in accordance with local codes, or in
the absence of local codes, with the
National Electrical Code, ANSI/NFPA
70, or the
Canadian
Electrical Code, CSA C22.2,
as applicable. For your convenience, this appliance has been
wired with a NEMA 5-15 cord and plug and should be plugged in to a corresponding NEMA 5-15
receptacle. The grounding prong SHOULD NOT BE CUT.
Cutting the grounding
prong will
void the manufacturers warranty
PRESSURE TEST
The appliance and its individual shut off valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of
1
/
2
psi
(3.5
kpa).
The appliance must be isolated from the gas supply piping system by closing its individual manual
shut off valve during any pressure testing of the gas supply piping system at test pressures equal
to or less than
1
/
2
psi
(3.5
kpa).
For Natural Gas:
when upper burners (3) are equipped
with No. 42 drill size orifice and lower burners (2) are
equipped with No. 32 drill size orifice.
For LP Gas:
when upper burners (3) are equipped with
No. 50 drill size orifice and lower burners (2) are equipped
with No. 41 drill size orifice.
Electrical diagrams for this appliance are located
behind the rear electrical box cover as well as in this
manual.
ENSURE
YOU DISCONNECT THE POWER
BEFORE OPENING REAR ENCLOSURE!