background image

INTRODUCTION

TECHNICAL SPECIFICATIONS

CONTROL ELEMENTS

ASSEMBLY & PREPARATION

OPERATING MODES

FILE TRANSFER

OKM ROVER UC 

MANUAL

Summary of Contents for Rover UC

Page 1: ...INTRODUCTION TECHNICAL SPECIFICATIONS CONTROL ELEMENTS ASSEMBLY PREPARATION OPERATING MODES FILE TRANSFER OKM ROVER UC MANUAL...

Page 2: ...ated with the delivery exploitation or usage of this material This documentation is available as presented and without any kind of warranty In no circumstances OKM takes responsibility for lost profit...

Page 3: ...S 11 4 ASSEMBLY AND PREPARATION 13 5 OPERATING MODES 14 5 1 ACTIVITY SCREEN 14 5 1 1 Pedometer Reset 15 5 1 2 Compass Calibration 15 5 2 3D GROUND SCAN 16 5 2 1 Preparing a 3D Ground Scan 16 5 2 2 Per...

Page 4: ...be successful and have a find during the course of your research The recognition of hidden and buried objects depends on a huge number of factors As you well may know there are different soil types al...

Page 5: ...uld have evaporated The unit is not weather proof and water or condensation can destroy the unit Avoid strong magnetic fields which may occur in places where there are large electric motors or unshiel...

Page 6: ...d form on it DO NOT store it in places that could get extremely hot DO NOT leave it in the trunk of a car where high temperatures could build up DO NOT spray lubricants or any type of cleaners solvent...

Page 7: ...isplay LCD 80 x 160Pixel Sample rate 240 values second Measurement resolution 15bit Interconnect Bluetooth 5 2 max distance 8m Operating temperature 5 60 C Storage temperature 10 70 C Air humidity 5 7...

Page 8: ...n this section you learn more about the fundamental use of all control elements for this measur ing instrument All connections inputs and outputs are explained in detail Telescopic Probe Smartwatch CO...

Page 9: ...owered on but is not connected to any Android device via Bluetooth Trigger LED blue Detector is powered on and connected to an Android device Smartwatch or Smartphone via Bluetooth The detector is rea...

Page 10: ...on B Long press Button B min 2 s to power on the Smartwatch or if Smartwatch is switched on to enter the Shutdown screen From here you can choose between Power off Reboot Power Save or Recent Task For...

Page 11: ...ur detector they must be paired with the Android device that you use to operate your detector via OKM Rover UC App Connect your headphones according to the following steps 1 Power on your headphones B...

Page 12: ...12 34 ASSEMBLY PREPARATION...

Page 13: ...D green fully charged Charging LED red charging 4 Start the OKM App on the Smartwatch and select the desired operating mode see chapter 5 OPERATING MODES on page 14 2 Release the lock by turning the g...

Page 14: ...le Explorer List of all scans that have been stored The scan files can be viewed and analy zed directly on the Smartwatch as well as transferred to a computer Settings Adjust general settings like lan...

Page 15: ...ting 1 After clicking on the icon the Rover UC App will start the calibration 2 Rotate very slowly around your own axis approx 16s for a complete 360 rotation while the Calibrating screen is visible 3...

Page 16: ...for fast scans Field Length Auto Impulse Mode Automatic Scan Mode Parallel 2 Select Customized to adjust the parameters individually 3 Choose the Field Length Auto Determine the length by pressing th...

Page 17: ...can Mode to determine how to walk over the scan field while scanning Parallel Scan all lines in the same direction Zigzag Scan all scan lines in zigzag style For further information please continue wi...

Page 18: ...gth Auto First press the Trigger to start your measurement Then take a step forward and press the Trigger again to measure the next impulse Continue in this way until you have reached the end of the f...

Page 19: ...e Step to the left again and scan the next line Repeat this until you reached the last scan line Read more about the scanning procedure in the 3D Ground Scan Guide see infobox on page 33 After finishi...

Page 20: ...e to scan in detail The less metals near to the surface the better your result in the operating mode 3D Ground Scan Moreover Magnetometer can be used to pinpoint objects during excavation If you have...

Page 21: ...t move the probe or your signal becomes unstable while scanning Press to perform a Ground Balance Please note that the Magnetometer can also react on metallic trash or contamination laying on the surf...

Page 22: ...al to the ground DO NOT turn swing or pivot the probe 1 Power on the detector and the Smartwatch Start the Rover UC App and select the operating mode Pinpointer 2 The Bluetooth connection to the detec...

Page 23: ...tic metal like iron includes a positive red and a negative blue amplitude When looking closely you can see even 2 ferromagnetic signatures The first signature starts with a positive amplitude and the...

Page 24: ...pressing Confirm by pressing or cancel with 1 Power on the detector and the Smartwatch Start the Rover UC App and select File Explorer 3 Open your scan for further analysis by tapping on the desired s...

Page 25: ...pective View by tapping on or rotate and scale individually with intuitive finger gestures pinch drag 5 Replay your measurement by tapping on 6 The replay will show you the complete scan generated lin...

Page 26: ...Deutsch DE EL English EN Espa ol ES FA Fran ais FR Italiano IT JA Polski PL RU T rk e TR ZH 5 6 2 Sound Toggle between ON and OFF The operating modes 3D Ground Scan and Magnetometer provide an acoust...

Page 27: ...ed with your scan file for fur ther analysis and documentation in the Visualizer 3D Studio software If you do not want to log the GPS location you can turn off GPS completely 5 6 5 App Theme Toggle be...

Page 28: ...nfi gured on the included Android device Activation may be necessary if you want to use your own Android device if you want to add further Android devices if you need to reset the pre configured devic...

Page 29: ...ion you will see the message No new update available Confirm with Otherwise download and install the new update 5 7 INFORMATION This section shows information concerning the detector App Version Teles...

Page 30: ...UC App When pairing Bluetooth for the first time proceed with the following steps on the notebook Click on and open Settings Devices 3 1 Power on the Smartwatch Start the Rover UC App and select File...

Page 31: ...firm the PIN 1 Click Pair on the Smartwatch 2 Click Connect in the Windows dialog Confirm with click on Done Scroll down in the dialog window and select More Bluetooth options Make sure your device is...

Page 32: ...en pairing the Rover UC App for the first time please make sure you have processed the steps in section 6 1 PAIRING BLUETOOTH on page 30 1 Power on the Smartwatch Start the Rover UC App and select Fil...

Page 33: ...all if you want to delete all transferred scan files from the device after transfer Confirm with OK to finish the import For more information on handling your detector optimizing 3D Ground Scans and c...

Page 34: ...Altenburg Germany we are developing and manufacturing geophysical detectors since 1998 Our unique detection technology helps to visualize buried objects and structures OKM GERMAN DETECTORS 49 3447 499...

Reviews: