Sensitivity 

Knob

Power Button  

with Operating LED

Volume 

Knob

Power Button with Operating LED: 

Push the Power Button to switch on the Control Unit. At first, 

the Operating LED starts blinking for about 2 seconds before it remains 

green

 

permanently. If 

the LED blinks rapidly before turning off, the internal battery is too low and must be charged (see 
chapter "4.1 Charging the Control Unit" on page 13).

If you are using Bluetooth Headphones, you see its pairing state by looking at the Operating LED. 
If the LED is

 

blue

 

the headphones are properly connected and ready to use as output source for 

any acoustic signals. More details about Bluetooth Headphones and the LED indications can be 
found in chapter "3.4 Bluetooth Headphones" on page 12.

To switch off the Control Unit, push the Power Button for at least 3 seconds until the Operating 
LED turns off.

Volume Knob

 (black cap): This knob regulates the volume 

of the acoustic output. Turning the knob to the left low-
ers the volume, turning it to the right raises the volume. 
If the value reaches its minimum or maximum, addition-
al turning in the same direction will have no decreasing 
or increasing effect. In this case, you will hear a double 
tone that indicates you reached the end of the adjustment 
range.

In case you need to connect Bluetooth Headphones, the 
Volume Knob can be utilized for pairing purposes. Please 
read chapter "Pairing new Bluetooth Headphones" for 
more information.

Sensitivity Knob

 (gray cap): This knob is used to regulate 

the sensitivity of the Search Coil. The higher the sensitivity 
the deeper you may find underground objects but the more 
noise and disturbances you may receive alongside metal 
signals.

Turning the knob to the left lowers the sensitivity, turning 
it to the right raises the sensitivity. If the value reaches 
its minimum or maximum, additional turning in the same 
direction will have no decreasing or increasing effect. In 
this case, you will hear a double tone that indicates you 
reached the end of the adjustment range.

If the sound output gets to noisy, you may apply a ground 
balance by pushing the Sensitivity Knob downwards. Read 
chapter "Ground Balancing" for more details about bal-
ancing your metal detector.

Summary of Contents for PULSE NOVA

Page 1: ...INTRODUCTION TECHNICAL SPECIFICATIONS CONTROL ELEMENTS ASSEMBLY MEASUREMENT TROUBLESHOOTING OKM PULSE NOVA MANUAL ...

Page 2: ...warranty In no circumstances OKM takes responsibility for lost profits usage or data losts interruption of business activities or all kind of other indirectly damages which developed because of errors in this documentation This instruction manual and all other stored media which are delivered with this package should only be used for this product Program copies are allowed only for security and sa...

Page 3: ...DELTA38 OMEGA38 7 2 4 SEARCH COIL DELTA18 OMEGA18 7 2 5 FRAME COIL XI104 7 3 CONTROL ELEMENTS 8 3 1 CONTROL UNIT 9 3 2 TELESCOPIC ROD 11 3 3 SEARCH COILS 11 3 4 BLUETOOTH HEADPHONES 12 3 4 1 Pairing new Bluetooth Headphones 12 4 ASSEMBLY 13 4 1 CHARGING THE CONTROL UNIT 13 4 2 MOUNTING THE CONTROL UNIT 14 4 2 1 Attaching the Carrying Strap 14 4 2 2 Mounting the Control Unit 14 4 4 ADJUSTING THE TE...

Page 4: ...and have a find The recognition of hidden and buried objects depends on various factors As you well may know there are different soil types all over the world with different levels of natural attenuation Variable soil properties can and will hamper and alter ultimate scan measurements Areas with an extreme amount of ground water vary ing clays sands and wet soils will make scanning more difficult ...

Page 5: ...cated range of values Use only approved chargers batteries and rechargeable batteries which are included within the scope of delivery 1 2 5 Data Correctness Data errors can occur if the power supply of the device or the batteries are too low the cables are too long the unit is operating to close to devices which sends out disturbances or atmospheric conditions electrical storms lightning etc 1 3 M...

Page 6: ...detector becomes less and less re sponsive and seems to have lost some of its original peak performance You can help prevent this from happening to your detector by following these basic care and protection guidelines Operate your detector exactly as recommended in this User Manual Use only the OKM Power Pack or other approved power supplies The search coil cable is hard wired to the search coil a...

Page 7: ... 115 x 200mm Weight 0 90kg 2 3 SEARCH COIL DELTA38 OMEGA38 Diameter Ø 375mm Height 45mm Cable Length approx 1 50m Weight approx 0 80kg Technology Bifilar Mono Coil High Voltage Pulse Induction Waterproof Yes 2 4 SEARCH COIL DELTA18 OMEGA18 Diameter Ø 175mm Height 45mm Cable Length approx 1 50m Weight approx 0 38kg Technology Bifilar Mono Coil High Voltage Pulse Induction Waterproof Yes 2 5 FRAME C...

Page 8: ...tal Detector with Standard Search Coil Delta38 The Search Coil is mounted at the bottom of the Telescopic Rod The Control Unit needs to be attached beneath the armrest detail Understanding the various ports and connectors makes it much easier to prepare the unit for operation Assembled Metal Detector with Standard Search Coil Delta38 The Search Coil is mounted at the bottom of the Telescopic Rod T...

Page 9: ... place where it gets connected Slider Plate This part is used to mount the Control Unit to the Telescopic Rod Thanks to the embedded magnet the Control Unit will keep in place when attached Read chapter 4 2 Mount ing the Control Unit on page 14 to learn more about assembling and disassembling the Con trol Unit to the Telescopic Rod Headphones Socket If you don t want to use Bluetooth Headphones yo...

Page 10: ... right raises the volume If the value reaches its minimum or maximum addition al turning in the same direction will have no decreasing or increasing effect In this case you will hear a double tone that indicates you reached the end of the adjustment range In case you need to connect Bluetooth Headphones the Volume Knob can be utilized for pairing purposes Please read chapter Pairing new Bluetooth ...

Page 11: ...cro for your own comfort Tab Locks Use these locks to extend or shrink the Telescopic Rod Open the tab to loose the connected shaft of the rod and tighten it after adjusting the length accordingly More details in chapter 4 4 Adjusting the Telescopic Rod on page 15 3 3 SEARCH COILS The Pulse Nova metal detector comes depending on the purchased pack with several Search Coils in different sizes 38cm ...

Page 12: ...cessful Bluetooth connection As soon as the Bluetooth connection between Control Unit and headphones has been estab lished the internal speaker will be disabled The Headphones Socket will not be disabled so any wired headphones that are connected to the Control Unit are still working independently 3 4 1 Pairing new Bluetooth Headphones To operate the Pulse Nova metal detector with any other wirele...

Page 13: ...tor at all When the internal battery gets low while working with the detector a low triple tone at increasingly shorter intervals will sound on your acoustic output This very unique tone will repeat to inform you about the low battery condition until the Control Unit switches off Recharge the battery by connecting the Power Charger or an OKM Power Pack The Charging LED indicates the status of the ...

Page 14: ...ap into the Loops of the Control Unit 4 2 2 Mounting the Control Unit When using the 18cm or 38cm Search Coil the Control Unit may be mounted to the Telescopic Rod 1 2 Place the Slider Plate of the Control Unit directly into the Slider Bracket of the Telescopic Rod Push it completely into the bracket until it snaps into place After the Control Unit has been attached to the Telescopic Rod you can c...

Page 15: ...ated Socket of the Control Unit 4 4 ADJUSTING THE TELESCOPIC ROD The length of the Telescopic Rod can be adjusted according to your own body height Adjust the length according to your own comfort Use the Tab Locks to loosen and tighten the single segments of the Telescopic Rod To adjust the rod length the Tab Locks needs to be opened 2 Extend the shaft to your desired length To fix the length lock...

Page 16: ...onto the Mounting Plate on top of the Telescopic Rod and push it gently to fix it You can remove the flashlight via the rubber band see steps 1 and 2 e g for charging The Pulse Nova metal detector includes an LED Flashlight that can be attached on the Tele scopic Rod This is very helpful for night searches or investigations in dark rooms or chambers ...

Page 17: ...inting up Assemble the coil by putting each end into the adjacent corner piece Each segment is equipped with a belt clip to mount the carrying straps You may change the position of the belt clips to adjust it to your individual needs The carrying straps must be attached to the Frame Coil in order to carry it The coil can be carried by 2 people whereas each person carries one single strap or by 1 p...

Page 18: ...tromag netic induction to create a reaction within metals This reaction within the metal object creates electrical conductivity or an anomaly which actually disturbs the flow of the current When this disturbance is realized the detector reports the anomaly The surface of the material being detected must be accessible to the current Various finishes and coverings may cause bad or weak readings An a...

Page 19: ... Coil Delta18 and Omega18 Search Coil Delta38 and Omega38 Frame Coil Xi104 Gold nugget ø 5mm 18cm 17cm Gold coin ø 20mm 23cm 25cm Gold ring ø 22mm 17cm 34cm Silver coin ø 24mm 22cm 35cm Silver coin ø 40mm 31cm 45cm 1EUR coin 28cm 43cm Beverage can 0 5l 65cm 110cm 155 cm Gas can 20l 115cm 180cm 255 cm Steel barrel DIN EN 210 115cm 180cm 310 cm 5 2 GROUND BALANCING The ground balance of the Pulse No...

Page 20: ...does take some practice Relax loosen up and find a comfortable grip on the handle Premature fatigue may result from gripping the handle too tightly an improperly adjusted rod or elbow support and limited body movement Hold the handle loosely Adjust the rod and elbow support for comfort and keep the elbow strap loose Use your arm shoulder and even your back a little to allow for a smooth even sweep...

Page 21: ...t is receiving feedback There is a signal then it goes away why Check your ground balance most likely you adjusted it in the field and have reset the unit and balanced it out The size of the item may be extremely small or it may lie just within the range of the detector I hear a signal then I can t find it again why The coil may be touching or just about to touch the ground and give a signal that ...

Page 22: ... Altenburg Germany we are developing and manufacturing geophysical detectors since 1998 Our unique detection technology helps to visualize buried objects and structures OKM GERMAN DETECTORS 49 3447 499300 0 49 162 419 2147 info okmdetectors com www okmdetectors com ...

Reviews: