DANGER:
If a gas leak cannot be stopped, or a fire occurs due to gas leakage, call the fire department.
Emergencies
Problem
Gas leaking from LP
cylinder.
Gas leaking between
LP cylinder and
connection.
Fire coming through
control valve connection
Grease fire or
continuous excessive
flames above cooking
surface.
Burner(s) will not light
using ignitor.
Continued on next
page.
Possible Cause
Possible Cause
•Mechanical failure due to rusting or
mishandling.
•Improper installation, connection not
tight, failure of rubber seal.
• Fire in burner tube section of burner due
to blockage.
• Too much grease buildup in trough.
GAS ISSUES:
• Burner not engaged with regulator control
• Obstruction in burner.
• No gas flow.
• Regulator Control Valve and LP cylinder
valve not fully connected.
ELECTRICAL ISSUES:
•Electrode cracked or broken; “sparks at
crack.”
•Electrode and burner are wet
•Wire and/or electrode covered with
cooking residue.
•Wires are loose or disconnected.
•Wires are shorting (sparking) between
ignitor and electrode.
Prevention/Solution
Prevention/Solution
•Replace LP cylinder.
• Remove regulator control valve from cylinder and
visually inspect for damage. See LP Cylinder Leak Test
and Connecting Regulator control valve to the LP Cylinder.
•Turn off control knob. Leave lid open to
allow flames to die down. After fire is out and grill is cold, remove
burner and inspect for spider nests or rust. See Natural Hazard
and Cleaning the Burner Assembly pages.
• Turn off control knob and LP cylinder valve. Leave lid open to
allow flames to die down. After cooling, clean food particles and
excess grease from inside firebox area, grease cup, and other
surfaces.
• Make sure regulator control valve is positioned inside of burner tube.
• Ensure burner tube is not obstructed with spider webs or other
matter. See cleaning section of Use and Care.
• Make sure LP cylinder is not empty.
• Remove LP cylinder. Clean threads on LP cylinder and regulator
control valve.
• Replace electrode(s).
Wipe dry with a cloth.
•Clean wire and/or electrode with rubbing alcohol and clean swab.
•Reconnect wires or replace electrode/wire assembly.
•Replace ignitor wire/electrode assembly.
Troubleshooting
regulator control valve
at burner/regulator
valve.
• Regulator Control Valve knob does NOT
stay down in ON positions.
• Replace regulator control valve.
• Regulator Control Valve knob does NOT
pop up in the OFF position.
• Replace regulator control valve.
Summary of Contents for CANYON COMBO 24203004
Page 33: ...ASSEMBLY ASAMBLEA OKLAHOMAJOES COM 33 4 K x 2 22 22 L x 2...
Page 35: ...ASSEMBLY ASAMBLEA OKLAHOMAJOES COM 35 7 6 30 x2...
Page 36: ...ASSEMBLY ASAMBLEA OKLAHOMAJOES COM 36 8 9 31 17 B x 4 D x 4 B x 4 D x 4 31 33...
Page 39: ...ASSEMBLY ASAMBLEA OKLAHOMAJOES COM 39 14 15 B x 2 D x 2 10 44 42 25...
Page 40: ...ASSEMBLY ASAMBLEA OKLAHOMAJOES COM 40 17 43 41 A x 4 39 16 17...
Page 41: ...ASSEMBLY ASAMBLEA OKLAHOMAJOES COM 41 18 19 X 40...
Page 42: ...ASSEMBLY ASAMBLEA OKLAHOMAJOES COM 42 20 20 M x 1 N x 1...
Page 43: ...ASSEMBLY ASAMBLEA OKLAHOMAJOES COM 43 21 21 18...