Housing & Bracket – HI11-TKHBL
1. Lens Cap with Heater
2. Temper
Glass
3. IR LED: 7pcs or 11pcs Super Power IR LED with Refractor
4. IR Board and IR Board Bracket
5. Universal IR Control Circuit Board: When the IR light turns on, it automatically adjusts the color to monochromatic through the universal
IR control circuit.
6. Camera
Bracket
7. Power Supply Unit: 24V AC input, 60VA
8. Blower
and
Blower
Bracket
9. Thermostat
Switch
10. Video Input BNC Male Connector: Connect to camera
11. Video Out BNC Female Connector: Connect to monitor
12. Terminal Board
13. Fuse Holder: With 250V / 3.15A fuse
14. AC IN Terminal block: 24V AC external power input
15. OUTPUT_1 Terminal block: Plug and fix the power cable of camera
16. OUTPUT_2 Terminal block: To power supply unit
17. VR: Adjust VR to set Infrared LED activation level
Factory default 80%
-- If there is not enough IR light, adjust the level to maximum 100%
18. Thermostat Switch: Turns on at 35
C / 95
F and turns off at 25
C / 77
F for Blower
19. Ground wire: To top cover
20. 12V DC Power-in jack: To camera / , outer-
Internal / Line Lock (AC Version Only)
When using a camera which requires a 24V AC power input, please run a separate power line to the camera
Internal / Line Lock (AC Version Only); Must use 24V AC camera with Line Lock (12V DC cameras do not have line lock).
21. Flying Bare Lead Wire: When the wire is not in use, cover it with the screw-on connector or tape the tip with tape to prevent damages
caused by the bare lead wire.
Camera