background image

Copyright © 2012 by OKINA USA. All Rights Reserved. 

 

P-044_P-045

 

** Replacing SS10C-C480DN 

 

R201204-V27

 

 

 

SS10C-C65H 

Indoor Ceiling Mount

 

SS10W-C65H  

Outdoor Wall Mount

 

 

 

 

10x Mini PTZ Camera 

 

         

 

 
 
 

USER MANUAL 

 

 

 FEATURES 

 

  1/4" Interline Transfer CCD, 650 TV Lines 

  10x Optical Zoom, 10x Digital Zoom (Max 100x Zoom) 

  F1.8, f=3.8~38mm focal length 

  0.7 lux (color) / 0.02 lux (B&W), 50 IRE 

 

Mechanical IR Cut Filter (ICR), 

Day & Night Function 

  360° Endless Pan ; 180° Auto-flip Tilt ; 95° Normal Tilt 

  127 Presets ; RS-485 Communication, max 255 cameras 

  Pelco-D & Pelco-P Selectable protocols 

  Vector Drive Technology: Pan/Tilt motions are done at the shortest path 

  4 Alarm Inputs – 

SS10W-C65H

 

  Fan & Heater – 

SS10W-C65H

 

 12V 

DC 

 

Indoor 

Outdoor

Summary of Contents for PTZ Series

Page 1: ...10x Optical Zoom 10x Digital Zoom Max 100x Zoom F1 8 f 3 8 38mm focal length 0 7 lux color 0 02 lux B W 50 IRE Mechanical IR Cut Filter ICR Day Night Function 360 Endless Pan 180 Auto flip Tilt 95 No...

Page 2: ...For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product CAUTION 1 Never p...

Page 3: ...the following conditions a When the power supply cord or plug is damaged b If liquid has been spilled or objects have fallen into the video product c If the video product has been exposed to rain or w...

Page 4: ...NG OSD MENU 11 RESERVED PRESET 11 PRESET 11 SWING 12 PATTERN 12 13 GROUP 13 OTHER FUNCTIONS 14 HOW TO USE OSD MENU 15 31 OSD DISPLAY OF MAIN SCREEN 15 GENERAL RULES OF KEY OPERATION FOR MENU 16 MAIN M...

Page 5: ...ard for mini PTZ Dome Arm Type Wall mount bracket is standard for Outdoor PTZ Dome For any returns please include all components listed above with original packaging in Resalable Condition Absolutely...

Page 6: ...6 DIMENSIONS Indoor Ceiling Mount Outdoor Arm Type Wall Mount With Pendant Pole Mount With L Type Wall Mount 5 04 128mm 5 127mm 7 36 187mm 4 2 107 7mm...

Page 7: ...wn below Pin 1 2 3 4 5 6 7 8 ID Value 1 2 4 8 16 32 64 128 Ex ID 5 Ex ID 10 Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off Off The range of ID is 1 255 Do not use 0 as Camera ID Factory d...

Page 8: ...the camera If you change the camera protocol by changing the DIP S W the change will be effective after you reboot the camera Factory default is Pelco D 2400 bps Pin 3 and Pin 4 is only for supplier s...

Page 9: ...r Input Voltage Range Current Consumption 12V DC 11V 18V DC 0 8 A RS 485 Communication For PTZ control connect the keyboard and DVR To control multiple cameras at the same time RS 485 communication li...

Page 10: ...camera The camera ID can be checked by reading DIP switch of the camera If your controller supports multi protocols the protocol must be changed to match to that of the camera If you changed camera pr...

Page 11: ...TO Call 177 Enter Sets Day Night Mode to AUTO Call 178 Enter Sets Day Night Mode to NIGHT Call 179 Enter Sets Day Night Mode to DAY Call 190 Enter Sets OSD Display Mode to AUTO Except Privacy Mask Cal...

Page 12: ...turns on its axis by 360 in CCW Counterclockwise direction Speed can be set up from 1 sec to 180 sec Set Preset To set Swing use OSD menu Dome Camera Setup Swing Setup Run Swing E g Run the first swin...

Page 13: ...rn Dome Camera Setup Pattern Setup Ctrl Pattern GROUP Function The group function allows running sequence of Presets Pattern and or Swings Max 8 group can be stored Each group can have max 20 action e...

Page 14: ...ates system powerful Privacy Zone Mask function is possible Global Local WB White Balance and AE Auto Exposure can be set up Image Setup independently for each preset There are 2 modes Global mode Loc...

Page 15: ...to Preset PATTERN When Pattern is in action SWG PRESET When Swing is in action UNDEFINE D When undefined function is called to run Preset Label The label stored for specific Preset Alarm Input This in...

Page 16: ...information and configuration Display Setup Enable Disable of OSD display on Main Screen Dome Camera Configure various functions of this camera Setup System Initialize Initializes system configuration...

Page 17: ...and press NEAR button to save PRIVACY ZONE MASK SETUP Display Setup Privacy Zone Select area in image to mask Mask No Select Mask number If the selected mask has already data camera moves as it was se...

Page 18: ...e Edit Mask Move camera to area to mask Then the menu to adjust mask size will be displayed Privacy Zone Size Adjustment Adjust mask size Use joystick or arrow buttons to adjust mask size Left Right A...

Page 19: ...soon as camera arrives at a preset Digital Zoom ON OFF Sets digital zoom function to ON OFF If this is set to OFF optical zoom function runs but zoom function stops at the end of optical zoom magnific...

Page 20: ...cker Manual x 128 1 120000 sec If Iris is set to Manual and Shutter Speed is set to ESC Shutter Speed should have highest priority If Shutter Speed is set to A Flicker to remove Flicker Shutter Speed...

Page 21: ...ou set this to Inverse the view in the screen is moving same direction with jog tilting If Normal is selected the view in the screen is moving reversely Freeze In Preset ON OFF At start point of prese...

Page 22: ...me position if there is no PTZ command during assigned Wait Time Alarm Input Setup For Outdoor PTZ SS10W C65H Dome Camera Setup Motion Setup Alarm Input Setup Match the Alarm sensor input to one of Pr...

Page 23: ...runs Label MAX 10 alphabets are allowed CAM Adjust GLOBAL LOCAL WB White Balance and AE Auto Exposure can be set up independently for each preset There are 2 modes Global mode Local mode The Global mo...

Page 24: ...r is cursor As soon as finishing selecting alphabet cursor moves to the next digit 2 Using Left Right Up Down of joystick move to an appropriate character from the Character set To choose that charact...

Page 25: ...reset is not defined UNDEFINED will be displayed as shown below When swing function runs camera moves from the preset assigned as the 1 st point to the preset assigned as the 2 nd point in CW Clockwis...

Page 26: ...l be displayed under selected pattern number Clear Pattern CANCEL OK Deletes data in current pattern Edit Pattern Starts editing pattern Edit Pattern Dome Camera Setup Pattern Setup Edit Pattern 1 By...

Page 27: ...ss NEAR key To cancel recording and delete recording data press FAR key GROUP SETUP Dome Camera Setup Group Setup Group Number 1 8 Selects group number to edit If a selected group number is not define...

Page 28: ...tion Note that selected item is displayed in reverse Move cursor Left Right to select items and move cursor Up Down to change each value EDIT GROUP 1 NO ACTION DWELL OPT 1 NONE 2 NONE 3 NONE 4 NONE 5...

Page 29: ...ct Action number and repeat Step 1 4 to edit selected Group 6 After finishing setting up all Action Press FAR key to exit Then cursor should be moved to SAVE Press Near key to save data EDIT GROUP 1 N...

Page 30: ...letes preset date swing data pattern data and group data Reboot Camera Reboots Zoom camera module Reboot System Reboots speed dome camera Initial Configuration Table Display Configuration Camera ID ON...

Page 31: ...Night Brightness Brightness Iris Iris Shutter Shutter AGC AGC SSNR SSNR SENS UP SENS UP Motion Configuration Motion Lock OFF Power Up Action ON Auto Flip ON Jog Max Speed 120 sec Jog Direction INVERSE...

Page 32: ...ndless Tilt 180 Auto flip 95 Normal Preset Preset 360 sec Manual 0 05 360 sec Proportional to zoom Swing 1 180 sec 127 Preset Label Camera Image Setting Pattern 4 Pattern 1200 Commands about 5 minute...