– 128 –
APPENDIX
No. 1
DIP-SW1
2 3 4 5 6 7 8
No. 1
DIP-SW2
2 3 4
B-1. Parallel Interface Type
ON
ON
OFF
OFF
DIP-SW 1
Switch 1-1
Command emulation
ON
Standard Mode
OFF
ESC/POS Mode
The factory settings of DIP switch are all on.
The functions of switches 1-2 through 1-8 will change according to the command
emulation that has been set using switche 1-1.
(1) Standard mode
Switch
Function
ON
OFF
1-1
Command emulation
Always ON
1-2
Should not be changed (Should be set to on)
1-3
Should not be changed (Should be set to on)
1-4
Sensor adjustment
Invalid
Valid
1-5
Pin #31 (INIT) reset signal
Valid
Invalid
1-6
Handshaking conditions
Offline or receive
Receive buffer full
(conditions for BUSY)
buffer full
1-7
Automatic status back function
Invalid
Valid
1-8
Should not be changed (Should be set to on)
(2) ESC/POS mode
Switch
Function
ON
OFF
1-1
Command emulation
Always OFF
1-2
Graphic adjustment
203 DPI
180 DPI
1-3
Should not be changed (Should be set to on)
1-4
Sensor adjustment
Invalid
Valid
1-5
Pin #31 (INIT) reset signal
Valid
Invalid
1-6
Handshaking conditions
Offline or receive
Receive buffer full
(conditions for BUSY)
buffer full
1-7
Automatic status back function
Invalid
Valid
1-8
Should not be changed (Should be set to on)