background image

3 - English

Safety Information, 

220/240-Volt Models

This product has been carefully designed to give years of safe, 
reliable performance. As with all electrical equipment, however, 
there are a few basic precautions that should be taken to avoid 
injury or damage:

Ensure this and all other documentation is both read 

carefully and retained for future reference.
Ensure all warning and instruction labels on the product are 

read, understood and followed in order to prevent any risk of 

injury.

This product may be heavy. Please check the weight of the 

product and take all necessary precautions to prevent the 

risk of personal injury.

The product must be placed on a flat solid surface strong 

enough to support its weight to prevent any risk of injury.

Ensure that there is adequate ventilation all around the 

product to prevent overheating and any risk of fire.
Keep the product away from direct heat sources such as 

radiators and out of direct sunlight to prevent any risk of 

overheating.

The power supply required for this product is 220-240 VAC, 

50/60 Hz. Refer to your product's rating label on the 

machine for full power rating details. Ensure that you have a 

suitable power supply before connecting the product. If in 

doubt contact your dealer or check with your local power 

provider.
Ensure both the product and mains power switches are in 

the OFF position before connecting the AC power cable.
Do not connect or disconnect the power plug with a wet 

hand as this may cause electric shock.
Always hold the power plug to connect/disconnect the power 

cable to/from the mains socket. Unplugging by pulling on the 

cable can cause fraying and may lead to fire or electric 

shock.

This product has an earthed plug as a safety feature and will 

only connect to an earthed socket. Do not attempt to defeat 

the earthing or there is a risk of fire or shock.
If using an extension cable or power strip ensure that the 

total current rating (amperes) of all connected equipment is 

less than the maximum rating of the extension cable, power 

strip or wall outlet. If the product is already supplied with a 

fitted power strip then no additional power strip or extension 

cable should be used to connect to the mains wall outlet. 

Otherwise, fire or shock may occur.
Ensure the power cable is routed so as not to be damaged or 

cause a trip hazard. If the cable becomes frayed or damaged 

replace it immediately to prevent any risk of shock.
Do not twist, constrict or knot the power cable as this can 

cause overheating which may lead to fire or electric shock.
Ensure the power socket to which the product is connected is 

easily accessible at all times and not obstructed.
Use only the power cable supplied. Using a power cable not 

intended for this product may lead to fire or electric shock.
To avoid risk of fire and electric shock, do not use the power 

cable supplied with this product for any other electrical 

equipment.

If you do not connect the power cord or any other cables 

only as directed in the User's Guide, this may result in a 

fire.

It is recommended that the machine is switched off prior to 

opening covers; otherwise there is a risk of electric shock. 

When the product cover is open, do not touch the fuser unit 

or print head as you may receive burns. Allow it to cool 

before touching.

If the product casing gets extremely hot or smoke, unusual 

smells or abnormal noises are emitted from the product, 

there is a risk of fire. Unplug the mains connector and 

contact your dealer. 
If the product has been knocked over or damaged, there is 

a risk of electric shock, fire and/or injury. Unplug the mains 

connector and contact your dealer.
If any liquid (for example water) is allowed to enter the 

product, there is a risk of fire. Unplug the mains connector 

and contact your dealer.

Do not place containers containing liquid on the product as 

electric shock, fire and/or injuries may occur.

If any foreign objects (for example clips) are allowed to 

enter the product, there is a risk of electric shock, fire and/

or injury. Unplug the mains connector before removing the 

object.

Do not introduce foreign objects into the ventilation holes or 

operate this product with any covers open or doors removed 

as electric shock, fire and/or injuries may occur.

Do not use an extremely flammable spray near the product 

as the product contains high temperature parts that may 

cause a fire.

Switch the product off before cleaning to prevent any risk of 

injury. Clean using a damp cloth. Do not use liquid or 

aerosol cleaners.

Ensure loose clothing and hair is kept clear of moving parts 

when the product is in operation to prevent possible risk of 

injury.

Do not carry out any operations on the product that are not 

specified in the User's Guide. This may result in electric 

shock, fire and/or injury.
Do not touch the battery if one is fitted to the product. 

There is a risk of explosion if the battery is replaced by an 

incorrect type. The product battery should not require 

replacement during the life of the product.
Do not throw toner cartridges or image drum cartridges into 

a fire as you may receive burns from a dust explosion.

After installing additional memory, hard disk drive, or any 

other internally fitted option, any covers removed or doors 

opened must be closed or replaced and secured to prevent 

risk of fire.

The acoustic noise of this product is less than 70 dB (A) as 

measured in accordance with EN ISO 7779.
The operating condition range for your product is: 15.6 to 

32.2°C and 20 to 80% RH.  Operation of the product outside 

this range could result in damage to the product.
If a scanner, finisher etc. is fitted, exercise care when 

moving these items so as to avoid risk of entrapment or 

personal injury.
If the product is installed on a cabinet or high capacity 

feeder, ensure wheel locks are applied once placed in final 

position for use, to prevent risk of movement or injury. 

Summary of Contents for MB780

Page 1: ...a 31 Servicio y Apoyo 33 Informaci n reglamentaria 36 Hojas de Informaci n sobre Seguridad de los Materiales MSDS 38 Mexico M xico Espa ol Informaci n de Seguridad 27 Informaci n sobre la garant a 31...

Page 2: ...comes damaged or frayed replace it immediately If you are using an extension cord or power strip with the product make sure that the total of the amperes required by all the equipment on the extension...

Page 3: ...e power cable supplied with this product for any other electrical equipment If you do not connect the power cord or any other cables only as directed in the User s Guide this may result in a fire It i...

Page 4: ...er s must be below all drawers but they cannot be used with the 2000 sheet drawer The optional 2000 sheet drawer must be below any other drawers At least one input drawer or spacer is required with th...

Page 5: ...nvironment MFP Machine Types supported MB790 A maximum of four 550 sheet drawers standard or optional are supported One 550 sheet drawer is part of the base unit so up to three additional optional dra...

Page 6: ...is over the original purchaser must return the Product shipping prepaid in the original shipping container or equivalent to Oki Data or an authorized Oki Data service center and assume the risk of los...

Page 7: ...You can easily create your own Personal Solutions Center providing up to the minute Oki information specifically for your product including Product news Manuals Drivers and utilities Material Safety...

Page 8: ...should not exceed five 5 0 To be certain of the number of devices that may be connected to the line as determined by the total RENs contact the local telephone company For products approved after Jul...

Page 9: ...t the sum of the RENs of all the devices does not exceed five Industry Canada IC Radio Interference Statements This Oki Data apparatus complies with the Class A limits for radio interference as specif...

Page 10: ...Exposure Dust inhalation skin contact Low acute inhalation toxicity As with exposure to high concentrations of any dust minimal irritation of the respiratory tract may occur Exposure not probable wit...

Page 11: ...Minimize dust generation during clean up Sweep up spill with non metallic broom and dustpan Contain for disposal Oil permeated sweeping compound may be useful in cleaning up spills Handling and storag...

Page 12: ...oduct user to determine at the time of disposal whether a material has been contaminated and should be classified as a hazardous waste Disposal is subject to local state and federal regulations Transp...

Page 13: ...anada Gazette Part II Vol 122 No 2 Registration SOR 88 64 31 December 1987 Hazardous Products Act Ingredient Disclosure List Canadian Transport of Dangerous Goods Regulations and Schedules Clear Langu...

Page 14: ...alimentation vitez de posez quoi que ce soit sur le cordon d alimentation ou de le placer dans une zone de passage Si le c ble est endommag ou effiloch remplacez le imm diatement Si vous utilisez une...

Page 15: ...n utilisez pas le c ble fourni ici avec un autre quipement lectrique Si vous ne connectez pas le cordon d alimentation ou d autres c bles en respectant la m thode donn e dans le Guide de l utilisateu...

Page 16: ...ous de tous les bacs mais ils ne peuvent pas tre utilis s avec le bac 2 000 feuilles Le bac 2 000 feuilles en option doit tre install en dessous de tous les autres bacs L utilisation de ce socle requi...

Page 17: ...en charge MB790 Jusqu quatre bacs de 550 feuilles standard ou en option sont pris en charge L unit de base comprend un bac 550 feuilles Vous pouvez donc ajouter jusqu trois bacs suppl mentaires en op...

Page 18: ...ations agr Oki pour tre r par au titre de la pr sente garantie Pour formuler une demande de r paration ou une r clamation en vertu de la pr sente Garantie limit e communiquez avec le centre de r parat...

Page 19: ...z le 1 856 222 5276 Canada uniquement composez le 1 905 238 4275 La pr sente Garantie limit e s applique ce Produit Oki Data Toutefois la proc dure suivre pour obtenir de l assistance peut varier l ex...

Page 20: ...pilotes et utilitaires fiche de donn es de sant s curit base de connaissances pouvant tre interrog e et plus encore Il suffit de prendre quelques minutes pour le configurer pour consulter votre Centr...

Page 21: ...nique doivent tre conformes aux r glements et exigences applicables de la partie 68 de la FCC et des exigences adopt es par l ACTA Un c ble t l phonique et une fiche modulaire conformes sont fournis a...

Page 22: ...rmettant d identifier la source de transmission de la t l copie consultez la rubrique sur la configuration de l identification du t l copieur dans la section Configuration du terminal du Guide de l ut...

Page 23: ...pour toute exposition des concentrations lev es de poussi re une irritation l g re des voies respiratoires est possible Exposition improbable dans le cadre de I utilisation pr vue Chronique Aucuns ch...

Page 24: ...rme un nuage de poussi res liminez toutes les sources d inflammation telles que les tincelles les flammes nues ou les d charges d lectricit statique afin d viter I inflammation de la poussi re Lors du...

Page 25: ...bable dans le cadre de I utilisation pr vue Le noir de carbone et le dioxyde de titane purs des composants mineurs de ce produit ont t class par l IARC dans le groupe 2B carcinog ne probable Ce classe...

Page 26: ...du fabricant 29CFR Partie 1910 1200 R glementation OSHA sur les Fiches Signal tiques 49CFR Table de la Liste des substances dangereuses UN Appellations r glementaires GE Gazette du Canada Partie II V...

Page 27: ...Evite da ar el cable de alimentaci n No coloque nada sobre el cable ni en un lugar por donde circulan personas Si el cable se da a o se desgasta c mbielo inmediatamente Si est utilizando un cable de e...

Page 28: ...el ctricas Para evitar el riesgo de que se produzcan incendios y descargas el ctricas no utilice el cable de alimentaci n que se suministra con este producto para otros equipos el ctricos Si no conec...

Page 29: ...mentadores y no se pueden utilizar junto con el alimentador de 2 000 hojas El alimentador opcional de 2 000 hojas debe colocarse debajo del resto de alimentadores Se necesita al menos un alimentador o...

Page 30: ...s de impresora multifunci n admitidos MB790 Se admiten hasta cuatro alimentadores de 550 hojas est ndar u opcionales Un alimentador de 550 hojas forma parte de la unidad base por lo que se permiten tr...

Page 31: ...s de reparaci n bajo dicha garant a Para hacer un reclamo o solicitud de servicio bajo esta Garant a Limitada comun quese con un centro de servicio autorizado de Oki Data o con Oki Data directamente p...

Page 32: ...omunic ndose con uno de los lugares de asistencia t cnica de la lista siguiente Solo espa ol llamar al 1 856 222 7496 Solo Canad llamar al 1 905 238 4275 Esta Garant a Limitada se aplica a esta la Pro...

Page 33: ...es y utilidades Hojas de Informaci n sobre seguridad de los materiales MSDS B squeda en bases de datos y mucho m s Para crear su centro personal solo tiene que emplear unos pocos minutos y en el futur...

Page 34: ...e la fecha de recepci n del Producto en el lugar en que pueda hacerse efectiva esta garant a 3 Se podr n adquirir refacciones en el lugar se alado en el punto No 1 anterior Esta Garant a Limitada no a...

Page 35: ...O RESPECTIVO DE GARANT A DESCRITO ANTERIORMENTE BAJO NINGUNA CIRCUNSTANCIA OKI DATA O CUALQUIERA DE SUS FILIALES SER RESPONSABLE ANTE UN COMPRADOR O CUALQUIER OTRA PERSONA POR DA OS ESPECIALES COLATER...

Page 36: ...ed telef nica deben ser cumplir con el Aparte 68 de a normativa de la FCC y los requisitos establecidos por ACTA Esta unidad se suministra con un cable telef nico y un enchufe modular La unidad est di...

Page 37: ...su transmisi n por fax para hacer estos cambios primero vea las instrucciones sobre c mo configurar su n mero de fax y su nombre bajo Configuraci n de su terminal en la Gu a del Usuario Requisitos ex...

Page 38: ...de polvo contacto con la piel Toxicidad por inhalaci n aguda baja Si se realiza una exposici n a altas concentraciones de cualquier tipo de polvo se pueden producir irritaciones m nimas en el tracto r...

Page 39: ...de polvo posible durante la limpieza Limpie el material derramado con una escoba y un recogedor no met licos Gu rdelo para desecharlo Para limpiar los derrames puede ser til alg n compuesto de limpie...

Page 40: ...Si se desecha el producto sin estrenar no constituir un tipo de residuo peligroso ni por su enumeraci n ni por sus caracter sticas Sin embargo seg n la RCRA Ley de Conservaci n y Recuperaci n de Recu...

Page 41: ...No 2 SOR DORS 88 64 31 diciembre l987 Ley sobre los productos peligrosos Lista de divulgaci n de los Ingredientes Reglamentos y programas canadienses para el transporte de productos peligrosos Versi n...

Page 42: ...ilmente acess vel Evite danificar o cabo de alimenta o N o coloque nada sobre ele nem o coloque no percurso de passagem das pessoas Se o cabo ficar danificado ou desgastado substitua o imediatamente S...

Page 43: ...trico n o use o cabo de alimenta o fornecido com este produto em qualquer outro equipamento el trico Se o cabo de alimenta o ou qualquer outro cabo n o for conectado exatamente segundo as instru es fo...

Page 44: ...e todas as gavetas mas n o podem ser usados com a gaveta de 2000 folhas A gaveta de 2000 folhas opcional deve ficar abaixo de todas as demais gavetas Esta base requer pelo menos uma gaveta de alimenta...

Page 45: ...multifuncionais compat veis MB790 No m ximo quatro gavetas com capacidade para 550 folhas padr o ou opcionais podem ser usadas Uma gaveta de 550 folhas faz parte da unidade b sica portanto at tr s gav...

Page 46: ...ica Autorizados Oki Data do Brasil Ficar sob responsabilidade do Adquirente o transporte do Produto at um dos Centros de Assist ncia T cnica Autorizados Oki Data do Brasil devendo o Adquirente arcar c...

Page 47: ...e telef nica das instala es devem estar em conformidade com as regras e requisitos da Parte 68 da FCC adotados pelo ACTA Um cabo telef nico com plugue modular em conformidade com as regras e requisit...

Page 48: ...e inserir as seguintes informa es no seu equipamento de fax Data e hora consulte Ajuste da data e hor rio na se o de configura o do terminal do Manual do Usu rio para obter instru es sobre como proced...

Page 49: ...ade aguda por inala o Da mesma maneira que quando h exposi o a altas concentra es de qualquer tipo de p pode ocorrer irrita o m nima do trato respirat rio Exposi o n o prov vel com o uso a que se dest...

Page 50: ...as ou descarga est tica para prevenir a igni o do p Minimizar a gera o de p durante a limpeza Varrer o derramamento com uma vassoura e p n o met licas Colocar em recipiente fechado para descarte Compo...

Page 51: ...rt cula sem outras classifica es PNOC nem regulamenta es PNOR 12 Informa es ecol gicas Mobilidade N o determinada Persist ncia degradabilidade N o determinada Outras informa es Nenhuma conhecida 13 Co...

Page 52: ...tances List ou s o isentos Classifica o do M xico Sa de 1 Inflamabilidade 1 Reatividade 0 16 Outras informa es Coment rios sobre revis es Nenhuma revis o significativa nas informa es de sa de e segura...

Reviews: