79
Adjust the heaters’ temperature
The each heater’s initial value is set with MEDIA REG MENU, and the value is automatically set for the heater’s
temperature.
Therefore, normally the heater control menu is not required.
The heater control menu is used to:
- Complete the temperature’s fine adjustment during the print operation; or
- Confirm the current heater temperature
Procedure to set the heater temperature
(2) With receiving the RIP data, heating is started.
- The heaters’ maximum setup temperature is as follows.
Afterheater: 70°C, Printheater: 55°C, Preheater: 55°C
- Even after the print is completed, the temperature
changed at this procedure remains as the heaters’
setup temperature, until the media is installed again or
the Printer is turned off.
Note that the heaters’ initial values set with MEDIA REG
MENU are not changed with this procedure.
When a media type is selected at installing media, initial
temperature values of each heater for the selected media
type are displayed on the menu.
When the heater temperature is set with the RIP’s print data
and job, the heater control menu’s temperature is
overwritten by the RIP’s temperature.
When the current temperature of the afterheater, printheater,
and preheater reaches the temperature that is 1°C lower than
the set temperature, the printer starts printing.
During the print operation the heaters’ temperature is
changed by specifying the setup temperature with the
heater control menu.
Aft 40 Prn 50 Pre 45
C) 40 C) +55 C) 45
HEATER
# A F T E R H E A T E R T
> 0 1 : 4 0 ° C
# P R I N T H E A T E R T
> 0 1 : 5 0 ° C
# P R I N T H E A T E R T
> 0 1 : 4 0 ° C
RIP data
(1) The heaters are standby with the initial
temperature registered with the applied
media.
(3) When the heater temperature increased
almost to the setup temperature, the print
operation is started.
(4) The heaters’ temperature is changed during
the print operation.
- To use the initial temperature values set on the
operation panel rather than the temperature set with
the RIP, set HEATER PREF in the MEDIA REG MENU to
HEATER PANEL.