<Description>
One of the following errors was detected in the Y motor servo control program.
- Overcurrent
- Servo interruption error
- Outsync error
- In-position timeout error
<Action>
Follow the instruction in the message displayed.
If this error occurs when there are actually no media jams, or there are no obstacles in the
carriage or media path, check the
Items to be Checked
on the table below, and perform the
actions starting from the top until the problem is solved.
No
Items to be Checked
Action
1
Linear scale smeared or scratched
Softly wipe the linear scale with a soft cloth or lint-free
paper dampened with ethanol. Be careful so that:
- The linear scale is not scratched, or
- The attached parts are not removed.
If the linear scale is damaged, replace it.
2
Linear encoder’s connector
connection
Check that the harness connector is connected securely
to the board’s connector.
3
The Plate-Fix(FFC) metal plate fixed
on the F
FC’s PCB-ASSY-HCB1M
Check that the screws are tightened.
4
FFC connector connection
Reconnect the FFC on both the PCB-ASSY-HCB1M side
and the PCB-ASSY-IPB5-100 side.
If the cable terminals are smeared, softly wipe them with a
soft cloth or lint-free paper dampened with ethanol before
connecting them.
5
The width of the V-shaped folded
part on the PCB-ASSY-HCB1M-side
FFC
Check that
the width of the V-shaped folded part on the
FFC is proper. If not, adjust it. For the adjustment
procedure, see
6
Y motor’s connector connection
Check that the three connectors below connecting the
motor unit and the board unit are connected securely
- Connector on the motor unit side
- Connector on the relay part
- Connector on the board unit side
7
SUS belt tension
Check that the SUS belt tension is within the adequate
range. If it is not within the range, adjust it.
8
Timing belt tension
Adjust it.
MEDIA JAM ERROR
1
LIFT THE LEVER
Summary of Contents for IP-6620
Page 567: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 5 Appendix 4 Blower Fan Wiring Diagram...
Page 568: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 6 Appendix 5 Actuator Wiring Diagram...
Page 572: ...OKI Data Infotech Corporation CONFIDENTIAL Appendix 10 Appendix 9 Subtank Unit Wiring Diagram...