OKI Data Infotech Corporation CONFIDENTIAL
Chapter 6 Parts Replacement (Disassembly/Reassembly)
6-63
6.8.4
PCB-ASSY-HCB1M
<Removal>
1.
Press the
CANCEL
button and the
POWER
button on the operation panel at
the same time to turn the printer off. Turn
off the main power switch at the back of
the printer.
2.
Lower the CAPPING-UNIT-MW to move
the carriage to the left.
3.
Remove:
- COVER(L)ASSY-MW; and
- COVER(Y-RAIL)-SL-MW.
For the procedure, see
4.
Remove the COVER-CARRIAGE-MW
(see
).
5.
Remove the COVER(HCB1) with five
fixing screws.