background image

4

Federal Communications 

Commission (FCC) Declaration of 

Conformity

1. Product Identification

Product Name: ES3640e MFP

2. Statement

This device complies with Part 15 of the FCC Rules. 

Operation is subject to the following two conditions: 

(1) This device may not cause harmful interference, 

and (2) this device must accept any interference 

received, including interference that may cause 

undesired operation.

3. Responsible Party

Oki Data Americas, Inc.

2000 Bishops Gate Boulevard

Mt. Laurel, NJ 08054-4620
1-800-654-3282 (1-800-OKI-DATA)

FCC Radio Frequency Interference 

Statement

This equipment has been tested and found to comply 

with the limits for a Class A digital device, pursuant to 

Part 15 of the FCC rules. These limits are designed to 

provide reasonable protection against harmful 

interference in a commercial environment. This 

equipment generates, uses, and can radiate radio 

frequency energy and, if not installed and used in 

accordance with the instructions, may cause harmful 

interference to radio communications. Operation of this 

equipment in a residential area is likely to cause harmful 

interference in which case the user will be required to 

correct the interference at his own expense.

Note:

It is the responsibility of the user to obtain the 

required shielded cable in order to ensure 

compliance of this equipment with FCC 

regulations.

Changes or modifications not expressly approved by Oki 

Data may void your authority to operate this device.

Industry Canada (IC) Radio 

Interference Statement

This Oki Data apparatus complies with the Class A limits 

for radio interference as specified in the IC Radio 

Interference Regulations.

European Union Council of the 

European Communities 

Statements of Conformance

Electromagnetic Conformance

This product complies with the requirements of the 

Council Directive 89/336/EEC on the approximation of 

the laws of the member states relating to 

electromagnetic compatibility.

Safety Conformance

This product is in conformity with Directive 73/23/EEC 

on the harmonization of the laws of Member States 

relating to electrical equipment designed for use within 

certain voltage limits.

Specifications

For additional specifications, see the on-line User's 

Guide.

Electrical

Voltage

120 (110 to 127) VAC; 60 Hz, ±2Hz
230 (220 to 240) VAC; 50 Hz, ±2Hz

Power

Standby

: 1300 W max.; average 200 W

Operating

: 1500 W max.; average 750 W

Power Cord*

: 15-amp, shielded

*Important!

Be sure to use the power cord supplied with 

the product. Use of a power cord not supplied 

with the product, or use of an extension cord, 

may result in overheating and could be a safety 

hazard.

Environmental

Temperature

Operating

: 50 to 89.6°F (10 to 32°C)

Max. Color Print Quality:

 62.6 to 80.6°F (17 to 27°C)

Power Off

: 32 to 110°F (0 to 43°C)

Storage (1 year maximum)

:  -14 to 110°F (-10 to 

43°C)

Relative Humidity

Operating

: 20 to 80% RH

Max. Color Print Quality:

 50 to 70% RH

Power Off

: 10 to 90% RH

Storage

: 10 to 90% RH

Product

Model #

Printer

N31200A

Scanner

N33133A

Stand

High Capacity Feeder

N31220A

2nd Tray

N31210A

Cabinet

70050901

Duplexer

N31230A

Finisher, 4-Tray

N31050A

Summary of Contents for ES3640eMFP

Page 1: ...f the product If you are not sure check with your dealer or with your local power company Your product has a grounded three prong plug as a safety feature This plug only fits into a grounded outlet If...

Page 2: ...s the right to use new and or refurbished parts in the warranty repair process If the product or a component of the product is being replaced the replacement product or component will be warranted for...

Page 3: ...ler from whom the product was purchased by contacting Oki Data directly at 1 800 654 3282 1 800 OKI DATA or by contacting one of the service locations listed below Canada Only call 1 905 238 4275 This...

Page 4: ...ity to operate this device Industry Canada IC Radio Interference Statement This Oki Data apparatus complies with the Class A limits for radio interference as specified in the IC Radio Interference Reg...

Page 5: ...t Not available Boiling Point Not available pH Not available Vapor Pressure Not available Vapor Density Air 1 Not available Evaporation Rate Butyl Acetate 1 Specific Gravity H2O 1 About 1 2 at 20 C 68...

Page 6: ...lly required Other Protective Equipment and or Hygienic Practices None Spill Cleanup Small Spills 1 Remove sources of ignition 2 Carefully clean up the spill with a wet cloth avoiding inhalation of fi...

Page 7: ...t available pH Not available Vapor Pressure Not available Vapor Density Air 1 Not available Evaporation Rate Butyl Acetate 1 Not available Specific Gravity H2O 1 About 1 2 at 20 C 68 F Solubility in W...

Page 8: ...mask leather gloves safety goggles 3 Vacuum or sweep the material into a bag or other sealed container then wipe up remainder with a wet cloth Waste Disposal Prevent release of material into natural w...

Page 9: ...Not available pH Not available Vapor Pressure Not available Vapor Density Air 1 Not available Evaporation Rate Butyl Acetate 1 Not available Specific Gravity H2O 1 About 1 2 at 20 C 68 F Solubility in...

Page 10: ...mask leather gloves safety goggles 3 Vacuum or sweep the material into a bag or other sealed container then wipe up remainder with a wet cloth Waste Disposal Prevent release of material into natural...

Page 11: ...t available pH Not available Vapor Pressure Not available Vapor Density Air 1 Not available Evaporation Rate Butyl Acetate 1 Not available Specific Gravity H2O 1 About 1 2 at 20 C 68 F Solubility in W...

Page 12: ...aste Disposal Prevent release of material into natural waters and sewers Follow appropriate federal state and local regulations Small amounts can be incinerated Careful Combustion can create harmful g...

Reviews: