43984801TH Rev.1
44 /
Oki Data CONFIDENTIAL
3. Parts replacement
3.3.7 OPE Cover-Assy
(1) Open the Rear-Cover-Assy.
(2) Open the Stacker-Cover-Assy.
(3) Remove the Cover-Side-R and Cover –Side-L. (Refer to 3.3.3/3.3.4)
(4) Remove the Plate-Cover-Shield-CU. (Refer to 3.3.5(2))
(5) Remove the screw (Silver)
①
. Remove the Film-Core-Holder
②
.
(6) Remove the FFC cable
③
from the CU board.
(7) Open the Cover-Assy-MPT.
(8) Pull Claw A by the arrow direction. Remove the clamp by pushing Claw B as the arrow direction.
Remove the OPE Cover-Assy
❹
.
(9) Installing is performed by the reverse procedure with removing.
(Note on removing / installing)
1. Beware of not to touch the DC motor inattentively (Do not rotate motor).
①
②
③
CU board
Stacker-Cover-Assy
Rear-Cover-Assy
Cover-Assy-MPT
❹
Claw A
Claw B
Claw B