PAGE 18
© 2019 OJ Electronics A/S
PLI: Power Limit 2/2
Enter 6 minutes in the PLI menu in order to reduce the
heating by 10%
Equation to calculate number of minutes that could be
entered in the PLI menu - when an average heating effect
is desired:
Average desired heating effect per m
2
Floor heating element output per m
2
(
1-
(
)
)
∗
60 min
Note!
If the result of the equation is negative then nothing
should be entered
The function is factory set to 0 minutes but can be set to
values between 0-30 minutes in steps of 1 minute
• Access the menu
• Scroll through the menu until you come to PLi
• Press the middle button to enter the pulse limit settings
• Use the top and bottom buttons to set the number
of minutes with which you want the heating to be
deactivated per hour
• Confirm your choice with the middle button
Menu structure:
PLi: 0 - 30
(Options available may vary depending on version)