PAGE 14
© 2019 OJ Electronics A/S
DEF: Frost Protection
This option allows you to set the parameters for a
possible frost protection function
An external signal can activate the frost protection
function, the thermostat will then maintain a fixed floor/
room temperature
The function is factory set to 8°C but can be set to values
between 5-10° in steps of 0 5°C
If the application is set to
C
and ”Frost protection” is
selected, the frost protection is set in absolute values in
per cent
• Access the menu
• Scroll through the menu until you come to DEF
• Press the middle button to enter the frost protection
settings
• Use the top and bottom buttons to set the temperature
you want to be the setpoint temperature when DEF is
activated
• Confirm your choice with the middle button
Menu structure:
dEF: 5 0 °C - 10 0 °C
(Options available may vary depending on version)