6
© 2012 OJ Electronics A/S
Type UCG/UDG
English
6
Press the
Up
or
Down
buttons to select one of the four types of
control:
ROOM:
The built-in room sensor is used.
Only room temperature is
controlled.
FLOOR:
A floor sensor is used. Only floor temperature is controlled.
REGULATOR:
The thermostat functions as a simple regulator and no
sensors are used.
ROOM LIMIT:
The thermostat controls room temperature while using
the external temperature sensor as a limit sensor. If you choose this
option, you must set a maximum and minimum temperature for the
limit sensor, so that the thermostat will switch the heating off or on
if the temperature on the floor reaches the maximum or minimum
temperature respectively. This can, for instance, be used to avoid
excessively high temperatures on wooden flooring (maximum limit) or
excessively cold temperatures on tiled/stone flooring (minimum limit).
7
Press the
OK
button.
8
If
FLOOR
or
ROOM LIMIT
is chosen, maximum and minimum floor
temperatures can now be set. Press the
Up
or
Down
buttons to set
the
High
temperature. Press
OK
and set the
Low
temperature. Press
the
OK
button.
9
Follow the
Exit Menu
procedure to exit the menu.
Please note:
Usually, the electrician who installed the thermostat will have
selected the correct type of temperature control for your application.
ROOM
FLOOR
REGULATOR
ROOM LIMIT
SETTINGS
TIME
DAY
CHILDLOCK
C°/F°
APPLICATION
OFFSET TEMP
READOUT
ADAPTIVE
DISPLAY
FACTORY RESET
EXIT
Display
I want to choose the information to be shown on the thermostat
display.
To do so, you must:
1
With
Active Display
(backlight on) press
OK
to activate the menu.
2
Press the
Up
or
Down
buttons until the
SETTINGS
option flashes.
3
Press the
OK
button.
4
Press the
Up
or
Down
buttons until the
DISPLAY
option flashes.
5
Press the
OK
button.
6
Press the
Up
or
Down
buttons to select whether or you wish to:
- display the
Clock
or not (On/Off),
- display the
Set temperature
or not (On/Off).
- You can also decide whether the temperature displayed is the Room
temperature, the Floor temperature (if a floor sensor is used) or the
Regulator temperature.
7
Press the
OK
button to confirm the settings as you work your way
through the various options in the
DISPLAY
submenu.
8
Follow the
Exit Menu
procedure to exit the menu.
Factory settings:
TIME:
ON
; SET TEMP.:
ON;
TEMP.:
FLOOR
FLOOR
SETTINGS
TIME
DAY
CHILDLOCK
C°/F°
APPLICATION
OFFSET TEMP
READOUT
ADAPTIVE
DISPLAY
FACTORY RESET
EXIT
On/Off
On/Off
Room/floor/regulator
Factory Reset
I want to return to the factory settings.
To do so, you must:
1
With
Active Display
(backlight on) press
OK
to activate the menu.
2
Press the
Up
or
Down
buttons until the
SETTINGS
option flashes.
3
Press the
OK
button.
4
Press the
Up
or
Down
buttons until the
FACTORY RESET
option
flashes.
5
Press the
OK
button. A submenu will appears.
6
Press the
Up
or
Down
buttons until the
RESET
option flashes.
7
Press the
OK
button.
8
Follow the
Exit Menu
procedure to exit the menu.
SETTINGS
TIME
DAY
CHILDLOCK
C°/F°
APPLICATION
OFFSET TEMP
READOUT
ADAPTIVE
DISPLAY
FACTORY RESET
EXIT
RESET
EXIT
Error Messages
E0 = Internal failure. Replace thermostat.
E1 = Internal sensor defective or short-circuited. Replace thermostat.
E2 = External sensor defective or short-circuited. Check external sensor.
Factory Settings for Automatic 5:2 Program
Days 1-5 (Monday - Friday)
Event
Time
Temperature
Morning
6:00 a.m. - 8:00 a.m.
77 °F / 25 °C
Out
8:00 a.m. - 4:00 p.m.
68 °F / 20 °C
Home
4:00 p.m. - 10:00 p.m.
77 °F / 25 °C
Night
10:00 p.m. - 6:00 a.m.
68 °F / 20 °C
Days 6-7 (Saturday - Sunday)
Event
Time
Temperature
Day
8:00 a.m. - 11:00 p.m.
77 °F / 25 °C
Night
11:00 p.m. - 08:00 a.m.
68 °F / 20 °C