2.5.4
2.5.4
Heating the pipes and hoses with heating cables
Heating the pipes and hoses with heating cables
The heating cables must run in direct contact
with the pipe surface. Loose cable does not
conduct heat into the pipings.
2.5.5
2.5.5
Technical data
Technical data
Heating cartridge capacity
40 W/230 V
Heating cartridge dimensions
10 x 50 mm
Heating cartridge electric cable
2500 mm
Heating cable
Self adjusting - capasity decreases as the
pipe temperature rises.
Heating cable capacity
230 V 45 W/m in +10 C°
Heating cartridge case may be hot
RPMARINES 30840641GB
21 (57)
2. Burner operation