Installation and operation manual
OilonCooling Ck

Read these instructions carefully before installation, use, or maintenance

Summary of Contents for OilonCooling Ck5

Page 1: ...M8015 2337EN 11 September 2023 Installation and operation manual OilonCooling Ck Read these instructions carefully before installation use or maintenance ...

Page 2: ......

Page 3: ...nit 11 3 5 Adjusting room temperature 12 3 6 Operating modes 12 3 7 Selecting fan speed 12 3 8 Setting a timer 12 3 9 Turbo function 13 3 10 Econo function 13 3 11 Quiet function 14 3 12 Sleep function 14 4 Maintenance 4 1 Tasks at the start and end of the heating season 15 4 2 Cleaning the air filter 15 4 3 Cleaning the cooling unit 16 4 4 Troubleshooting 16 5 Technical data 5 1 Technical data 17...

Page 4: ...2 20 M8015 2337EN ...

Page 5: ...on The CAUTION symbol indicates a hazard that may result in an injury Pay attention The NOTICE symbol indicates a risk of damage to the equipment components or surroundings The i info symbol indicates important information as well as useful tips and hints Keep these instructions as well as the electrical diagrams available near the device Installation or commissioning of the appliance is to be car...

Page 6: ...extended period of time disconnect power from the cooling unit s main switch 1 2 Delivery contents Check the contents of the delivery immediately If some of the accessories specified in the order are not included in the delivery notify the equipment dealer within five days The cooling unit is delivered with an installation kit for connecting one cooling unit into a heat pump s brine circuit If you...

Page 7: ...e packaging Remove the cardboard packaging from around the product Check the unit for transportation damage If there is damage report the damage immediately to the carrier who delivered the unit M8015 2337EN 5 20 ...

Page 8: ...nit The location is optimal for air circulation within the room A condensate drain can be installed conveniently The unit is not next to a doorway The installation height is correct Making a mounting box for the cooling unit A service hatch will be mounted inside the mounting box at the edge of the box The cooling unit requires a mounting box for installation This box must be insulated as it exten...

Page 9: ...ed bars Install washers as shown in the image Cooling unit installation 1 Fasten the mounting box between ceiling structures 2 Carefully lift the cooling unit into place and mount corner brackets onto the threaded bars 3 Adjust the height using the washers and nuts Consider the final height of the ceiling lining 4 Tighten the fastening nuts 5 Fasten the grille in place with the supplied fastening ...

Page 10: ...stallation To prevent air pockets cut the condensate drain as short as possible and use a downward slope min 2 Minimum water seal depth 50 mm The highest point in the condensate drain must not be higher than 200 mm from the top of the cooling unit Carefully insulate the condensate drain pipe If there are several cooling units in the room you can chain the condensate drain pipes as shown in the ima...

Page 11: ...Two pipe system Power supply for valve actuator Protective earth M8015 2337EN 9 20 ...

Page 12: ...d keylock 8 Clock setting Pos Function 9 Room temperature setting 10 Power On Off 11 Timer Off and Off 12 Quiet function 13 Air flow vane 14 Air flow direction 15 Reset button Batteries The batteries 2 pcs AAA are under a sliding lid at the lower section of the remote control To fully remove the sliding lid lift slightly from the top middle part of the lid and slide downwards Place the batteries t...

Page 13: ... VANE button to browse between different vane positions 3 3 Setting the time 1 Remove the sliding lid Lift slightly from the top middle part of the lid and slide downwards 2 Press the small Clock button with the tip of a pencil or similar tool The clock icon and the time will start flashing on the remote control screen 3 Set the time with the up and down arrow To browse through numbers faster keep...

Page 14: ... a heating system the unit will operate at the set temperature AUTO The unit will operate in COOL or HEAT mode depending on the set temperature and the current room temperature 3 7 Selecting fan speed Scroll between fan speed modes by pressing the fan button repeatedly Available modes AUTO automatic LO slow MED medium HI high In AUTO mode the unit functions automatically The system detemines the f...

Page 15: ...ilable in COOL mode HEAT mode if the unit is connected to heating and AUTO mode Activate and deactivate the function by pressing the Turbo button When the TURBO function is on the text TURBO is shown on the remote control screen The set temperature and fan speed will not be displayed The Turbo function will be automatically deactivated when Temperature reaches 18 C in COOL mode Temperature reaches...

Page 16: ...automatically increase by 1 C in one minute 3 12 Sleep function The Sleep function automatically adjusts the room temperature setting one hour after the function has been activated Activate or deactivate the SLEEP function by pressing the Sleep button In COOL mode the unit will automatically increase the set temperature by one degree after one hour In HEAT mode the unit will automatically decrease...

Page 17: ...mote control Outside the cooling season it is recommended to run the equipment for a short time every 2 months This will lengthen the life of the circulation pump 4 2 Cleaning the air filter Clean the air filter regularly If the air filter is dirty air flow will be weaker which will increase power consumption In extremely dusty environments clean the air filter once every two weeks or as often as ...

Page 18: ...nit works but doesn t provide enough cooling Check the room temperature setting Check if the air filter is dirty or clogged Check if apartment doors or windows are closed Check if air flow from the cooling unit is blocked Check if the unit s brine circulation is blocked Check the brine circulation for air bubbles Check that the brine circuit pump is operating correctly There is steam coming out of...

Page 19: ... recommended installation conditions brine inlet temperature 7 C indoor temperature 27 C The coefficient of performance calculation accounts for one circulation pump 5 2 Dimensions Main dimensions mm Dimensions portion embedded in the ceiling Model Height Width Depth Height Width Depth Ck5 65 720 720 280 574 574 Ck9 67 950 950 320 844 844 Dimensional drawings Ck5 Dimensions Ck5 ver 1 CD condensate...

Page 20: ...Dimensional drawings Ck9 Dimensions Ck9 ver 1 CD condensate drain connection 5 3 Wiring diagram Wiring diagram two pipe system 18 20 M8015 2337EN ...

Page 21: ...ms 2000 unless separately agreed between the parties in writing Title The title to the Products is transferred to the Customer after the Supplier has received full payment for the Products Warranty period and warranty contents The Supplier provides a two 2 year warranty for their Products effective from the agreed delivery date The warranty is valid only in Finland During the warranty period the m...

Page 22: ...ion of liability The Supplier shall not under any circumstances be liable for indirect damages excluding damages that the Supplier has caused with willful intent or gross negligence The Supplier s maximum liability is always limited to the value of the delivered Products To the extent that claims are raised against the Supplier based on product liability damages for which the Supplier could be lia...

Page 23: ......

Page 24: ...OILON GROUP P O Box 5 FI 15801 LAHTI FINLAND Tel 358 3 85 761 Fax 358 3 857 6239 Email info oilon com www oilon com Contact information of Oilon dealer Date of installation ...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ......

Page 29: ......