3.4. Additional equipment control
Additional equipment has to be ordered separately, and is not in use in standard models.
3.4.1.
Cooling circuit 1
If cooling circuit is installed to ground source heat pump, cold water from drilled well can be
used for cooling with air conditioner. Ground source heat pump cannot be used for compressor
cooling, but it can be used for so called “passive cooling”.
User can make settings for
•
room temperature at cooling mode
•
operating mode (automatic or off)
•
start-up option for cooling circuit.
Start-up options are
•
24/h day, when cooling is continuously on
•
heating circuit time program
•
time program 5
With setting 24 h/day cooling is continuously on.
With heating circuit time program cooling circuit operates according to heating circuit 1.
Time program 5 can be set as other time programs. Time program 5 does not have actual
function, so it can be used to control cooling circuit on and off
3.4.2.
Solar heating
Settings for Solar system heating are set at the factory or during commissioning.
Control system uses temperature differences to direct heat into different locations. Values and
system settings are either factory settings or they have been updated during installation.
3.4.3.
Swimming pool
At Swimming pool menu level you can set temperatures for pool heating using solar power or
ground source heat pump. Solar collector setting should always be higher than ground source
heat pump setting.