F/C-DP  V-out 

I-out 

F/C-DP  V-out 

I-out 

F/C-DP  V-out 

I-out 

F/C-DP  V-out 

I-out 

-45 

0.000  4.000 

-11 

1.259  8.030 

23 

2.519  12.059 

57 

3.778  16.089 

-44 

0.037  4.119 

-10 

1.296  8.148 

24 

2.556  12.178 

58 

3.815  16.207 

-43 

0.074  4.237 

-9 

1.333  8.267 

25 

2.593  12.296 

59 

3.852  16.326 

-42 

0.111  4.356 

-8 

1.370  8.385 

26 

2.630  12.415 

60 

3.889  16.444 

-41 

0.148  4.474 

-7 

1.407  8.504 

27 

2.667  12.533 

61 

3.926  16.563 

-40 

0.185  4.593 

-6 

1.444  8.622 

28 

2.704  12.652 

62 

3.963  16.681 

-39 

0.222  4.711 

-5 

1.481  8.741 

29 

2.741  12.770 

63 

4.000  16.800 

-38 

0.259  4.830 

-4 

1.519  8.859 

30 

2.778  12.889 

64 

4.037  16.919 

-37 

0.296  4.948 

-3 

1.556  8.978 

31 

2.815  13.007 

65 

4.074  17.037 

-36 

0.333  5.067 

-2 

1.593  9.096 

32 

2.852  13.126 

66 

4.111  17.156 

-35 

0.370  5.185 

-1 

1.630  9.215 

33 

2.889  13.244 

67 

4.148  17.274 

-34 

0.407  5.304 

1.667  9.333 

34 

2.926  13.363 

68 

4.185  17.393 

-33 

0.444  5.422 

1.704  9.452 

35 

2.963  13.481 

69 

4.222  17.511 

-32 

0.481  5.541 

1.741  9.570 

36 

3.000  13.600 

70 

4.259  17.630 

-31 

0.519  5.659 

1.778  9.689 

37 

3.037  13.719 

71 

4.296  17.748 

-30 

0.556  5.778 

1.815  9.807 

38 

3.074  13.837 

72 

4.333  17.867 

-29 

0.593  5.896 

1.852  9.926 

39 

3.111  13.956 

73 

4.370  17.985 

-28 

0.630  6.015 

1.889  10.044 

40 

3.148  14.074 

74 

4.407  18.104 

-27 

0.667  6.133 

1.926  10.163 

41 

3.185  14.193 

75 

4.444  18.222 

-26 

0.704  6.252 

1.963  10.281 

42 

3.222  14.311 

76 

4.481  18.341 

-25 

0.741  6.370 

2.000  10.400 

43 

3.259  14.430 

77 

4.519  18.459 

-24 

0.778  6.489 

10 

2.037  10.519 

44 

3.296  14.548 

78 

4.556  18.578 

-23 

0.815  6.607 

11 

2.074  10.637 

45 

3.333  14.667 

79 

4.593  18.696 

-22 

0.852  6.726 

12 

2.111  10.756 

46 

3.370  14.785 

80 

4.630  18.815 

-21 

0.889  6.844 

13 

2.148  10.874 

47 

3.407  14.904 

81 

4.667  18.933 

-20 

0.926  6.963 

14 

2.185  10.993 

48 

3.444  15.022 

82 

4.704  19.052 

-19 

0.963  7.081 

15 

2.222  11.111 

49 

3.481  15.141 

83 

4.741  19.170 

-18 

1.000  7.200 

16 

2.259  11.230 

50 

3.519  15.259 

84 

4.778  19.289 

-17 

1.037  7.319 

17 

2.296  11.348 

51 

3.556  15.378 

85 

4.815  19.407 

-16 

1.074  7.437 

18 

2.333  11.467 

52 

3.593  15.496 

86 

4.852  19.526 

-15 

1.111  7.556 

19 

2.370  11.585 

53 

3.630  15.615 

87 

4.889  19.644 

-14 

1.148  7.674 

20 

2.407  11.704 

54 

3.667  15.733 

88 

4.926  19.763 

-13 

1.185  7.793 

21 

2.444  11.822 

55 

3.704  15.852 

89 

4.963  19.881 

-12 

1.222  7.911 

22 

2.481  11.941 

56 

3.741  15.970 

90 

5.000  20.000 

Table 1—Analog Output Table 

Summary of Contents for DPSC-35XR

Page 1: ...ER KIT SF SLS 553 A Phone 410 820 5111 Toll Free 800 626 7713 Fax 410 822 9633 www ohmicinstruments com Sales sales ohmicinstruments com Service service ohmicinstruments com Ohmic Instruments 3081 Elm...

Page 2: ...2 Ohmic Instruments 2014...

Page 3: ...tion 5 Operation 6 RS 232 Interface 6 Recalibration 7 Special Order 8 Mounting Template 9 Wiring Diagram 10 Alarm Reset Wiring 11 Analog Output Table 12 Sensor Precautions 13 Specifications 13 Logging...

Page 4: ...oped by OHMIC In struments The program utilizes psychrometric equations published by ASHRAE American Society of Heating Ventilation and Air Condi tioning Engineers and referenced to the Hyland Wexler...

Page 5: ...and RS 232 interface cable should be rout ed away from and in a separate conduit from the power cable The relay is normally open dry contact which closes when the dew point exceeds the set point Plac...

Page 6: ...nt time is required for stabilization For most air drying systems 5 to 15 minute stabilization time is typical Most probes exhibit negligible drift how ever as contaminates accumulate on the surface t...

Page 7: ...re in a comma delimited format that can be cop ied and pasted into a spread sheet program if desired Communications Commands All commands are in upper case characters set your CAPS LOCK on n indicates...

Page 8: ...ra cy When returning DPSC 35XR s for service and recali bration be sure to include the corresponding probes SPECIAL ORDER For a nominal fee the DPSC 35XR can be retrofitted by Ohmic with ei ther or bo...

Page 9: ...9 Figure 1 DPSC 35XR Mounting Template Template drawing is to be used on installation side of enclosure...

Page 10: ...10 Figure 2 Card Wiring Diagram...

Page 11: ...70 ohm resistor is on the PC board as shipped Connect alarm sonalert etc to terminals 4 and 5 Connect a momentary nor mally closed pushbutton switch across terminals 3 and 4 Retain the supplied jumper...

Page 12: ...778 4 1 815 9 807 38 3 074 13 837 72 4 333 17 867 29 0 593 5 896 5 1 852 9 926 39 3 111 13 956 73 4 370 17 985 28 0 630 6 015 6 1 889 10 044 40 3 148 14 074 74 4 407 18 104 27 0 667 6 133 7 1 926 10...

Page 13: ...stion Never sample air of gases with oil mist or separated water VI Chemical Contamination Exposure to corrosive or reactive chemicals should be avoided Chemicals such as sulfides acids and mercury wi...

Page 14: ...about four and a half minutes Uploading will not clear the logger memory this makes repeated up loading of the same data possible Data will be stored in the nonvolatile memory incorporated into the lo...

Page 15: ...he instrument returned transportation prepaid SHIPPING TO MANUFACTURER FOR REPAIR OR ADJUSTMENT All shipments of Ohmic Instruments products should be made via United Parcel Service or Best Way prepaid...

Page 16: ...16...