OHM
(
ChongQing
)
Electronic Technology CO.,LTD.
Tel: 023-68151154 Fax: 023-68151154-803 Service:400-920-9120
Ver.: 2016.01.1.0.3 Operating Manual for TCS-C Page 25 of 28
Crane Radio Control Equipment Safety Certificate
Protection grade
IP65
Execution element
Digital-electronic Double
CPU real-time control
Frequency control
PLL
(
phase lock loop
)
Address code
32 Bit
Control distance
>
100m
Transmitter type
joystick type
Transmitter power
supply
1
、
3.6VDC 2
、
6.0VDC (1500mAh nickel-hydrogen battery pack)
Working current of
transmitter
≤
80 mA (except special system)
Transmitter
undervoltage alarm
Sound-light alarm
Transmitter fault alarm
display or LED (Multiple combined sound-light alarms)
Power-saving protection
Auto shutdown (set to 0-30min)
Transmitter antenna
Built-in type
Receiver power supply
42-250VAC
、
10-30VDC
、
220/380VAC (3 options)
Rated power of receiver
≤
10W
Receiver fault display
LED working/failure status display
Output mode
Fully airtight relay output
Non-standard customized CANOPEN
Relay contact capacity
4A/250VAC
Output interface
Terminal output (including tube connection)
Non-standard HAN32/ HAN50 core heavy-type connectors can be
added
Receiver antenna
External type
Standard accessories
Receiver antenna
1 set
Receiver shock pad
4 pieces
Receiver installation
screw
4 sets
Operating Instructions
1 copy