![OHM PATCH PANEL PP-1 User Manual Download Page 6](http://html1.mh-extra.com/html/ohm/patch-panel-pp-1/patch-panel-pp-1_user-manual_3528758006.webp)
6
1 Trip Switch
To turn on the unit put the switch to on.
Unit will trip out automatically if a short circuit is
detected.
2 Power Connectors
4 x male Neutrik Powercon connectors to take
inline female Neutrik Powercon Plug type
NAC3FCB.
Wired as follows:
L = Live: Brown
B = Neutral: Blue
E = Earth: Yellow /Green
©
©
5 Ethernet Connector input
The Ethernet connector accepts RJ-45 connector
for networking. Built into the connector is a yellow
and green LED indicator. the green indicator is lit
when an amplifier is connected to the network.
The yellow shows any network activities. Use
either the RJ45 on the front or rear of Patch Panel.
Do not connect to both as they are wired together.
This connects to external router, from the external
router you can connect to either a network or PC.
You can use as many switches as you need but
make sure there is only one router built into your
network. A router with DCHP is needed to assign
the IP addresses to the units.
3 Inputs Binding Posts
Accepts Pomona plug, wired internally to the
4 way and 8 way Speakon connectors on the
front panel. See page 7 for wiring
information.
4 Ethernet Router Connectors Outputs
The Ethernet connector accepts RJ-45 connector
for networking. Built into the connector is a yellow
and green LED indicator. the green indicator is lit
when an amplifier is connected to the network.
The yellow shows any network activities.
To connect amplifiers to the network, use a
standard Ethernet cable. Up to four amplifiers can
be connected to one unit.
REAR PANEL
1
2
5
6
7
3
4
6 Inputs Channel A/B on female XLR
Electronically balanced input sockets accept
XLR male connectors. Parallel wired to
inputs1/2 on front panel.
Wired as follows:
Pin 1 = Ground,
Pin 2 = Hot,
Pin 3 = Cold.
7 Input Links Channel A/B on male XLR
Electronically balanced input link sockets
accept XLR female connectors. Parallel wired to
inputs links ½ on front panel.
Wired as follows:
Pin 1 = Ground,
Pin 2 = Hot,
Pin 3 = Cold.
MAINS OUTLETS USE NEUTRIK POWERCON PLUG NAC3FPB MAXIMUM 20 AMP
TRIP
SWITCH
PATCH PANEL
1
2
3
4
INPUT
AMP 2
AMP 1
AMP 3
AMP 4
ETHERNET ROUTER RJ45
INPUT B
LINK B
INPUT A
LINK A
AMP 1
AMP 4
B
A
AMP 3
B
A
AMP 2
B
A
B
A
AMP 1
AMP 4
B
A
AMP 3
B
A
B
A
AMP 2
A
B
WELLINGTON CLOSE • PARKGATE • KNUTSFORD • CHESHIRE • WA16 8XL • Tel. +44 (0)1565 654641 • e-mail: [email protected] • www.ohm.co.uk
OFF
ON
PUSH
PUSH
PUSH