OHM PATCH PANEL PP-1 User Manual Download Page 5

PP-1 PATCH PANEL

5

FRONT PANEL

9 & 12 Inputs 1 & 2 on female XLR

Electronically balanced input sockets accept

XLR male connectors. Parallel wired to inputs

A/B on rear.

Wired as follows:

Pin 1 = Ground,

Pin 2 = Hot,

Pin 3 = Cold.

13 Output 4 way Neutrik Speakon

Connectors

©

©

Accepts 4 way Neutrik

Speakon plug

connector NL4FC. Wired internally to the rear

Binding Posts.

1 Backlit Logo (Blue)

Indicates that the Patch Panel is switched on.

Powered by maintenance free LED’s.

2 Ethernet Connector (RJ45)

Use a standard network cable to connect up to

four amplifiers to a single network.

Important: Use either the RJ45 on the front or

rear of Patch Panel. Do not connect to both as

they are wired together.

3 Outputs 8 way Neutrik Speakon

Connectors

©

©

Accepts 8 way Neutrik Speakon plug

connector NL8FC. Wired internally to the rear

Binding Posts.

3

6

5

1

2

7

4

OPERATING INSTRUCTIONS

8

11

14 Sequencer On/Off Button

This button enables the amps to be turned on

in sequence. After an interruption in mains

supply the sequencer will automatically

restart.

USB LIGHT

ASSIGNABLE

INTERNAL

MATRIX

2

INPUT 2

LINK 2

LINK 1

INPUT 1

1

3

4

SPEAKER 2

RJ45

SEQUENCER

MAINS

230V~

50Hz

32A

LIVE

EARTH

POWER 4

POWER 1

POWER 2

POWER 3

NEUTRAL

PUSH

PUSH

PUSH

SPEAKER 1

12

15

13

14

SPEAKER 1

4 USB Sockets

2 x USB sockets to take USB peripherals such

as LED Gooseneck Lights 1 x provided.

5 Earth Indicator LED (Green)

Indicates that the Earth has been correctly

wired. Will not light if wiring is incorrect.

6 Live Indicator LED (Red)

Indicates that the Live has been correctly

wired. Will not light if wiring is incorrect.

7 Neutral Indicator LED (Blue)

Indicates that the Neutral has been correctly

wired. Will not light if wiring is incorrect.

8 Mains Input Single Phase C32 Socket.

Accepts female C32 Plug (Provided). Ensure

correct wire thickness and configuration is

used.

9

10

10 & 11 Input Links 1 & 2 on male XLR

Electronically balanced input link sockets

accept XLR female connectors. Parallel wired to

inputs links A/B on rear.

Wired as follows:

Pin 1 = Ground,

Pin 2 = Hot,

Pin 3 = Cold.

15 Sequencer Indicator LED’s (Red)

Lights up as to indicate the amplifiers have

powered up.

Summary of Contents for PATCH PANEL PP-1

Page 1: ...PP 1 PATCH PANEL USER MANUAL...

Page 2: ...ion USB Goose Neck Light Dimensions H x W x D mm Weight Kgs AC 230V 50HZ MCB Rated at 32 Amps C32 Socket provided Live Neutral Earth Sequencer 1 to four Powercon NAC3MPB Push on Push off switch Inputs...

Page 3: ...oltage within the unit that may constitute a risk of electric shock The exclamation mark triangle is used to alert the user to important operating or maintenance instructions in the literature accompa...

Page 4: ...aterials for use should you transport or ship the unit in future PP 1 Patch Panel Mounting Front and rear mountings are fitted to each unit which conform to standard 19 rack strip specifications We re...

Page 5: ...terruption in mains supply the sequencer will automatically restart USB LIGHT ASSIGNABLE INTERNAL MATRIX 2 INPUT 2 LINK 2 LINK 1 INPUT 1 1 3 4 SPEAKER 2 RJ45 SEQUENCER MAINS 230V 50Hz 32A LIVE EARTH P...

Page 6: ...front panel See page 7 for wiring information 4 Ethernet Router Connectors Outputs The Ethernet connector accepts RJ 45 connector for networking Built into the connector is a yellow and green LED indi...

Page 7: ...1 Channel A black Connect to amp 1 Channel B red Connect to amp 1 Channel B black Pin 1 Pin 1 Pin 2 Pin 2 Pin 3 Pin 3 Pin 4 Pin 4 Connect to amp 4 Channel A red Connect to amp 4 Channel A black Conne...

Page 8: ...urope com OHM EUROPE Guangzhou OHM Audio Co Limited 3 1 Huancun Road Caibian Village Donghaun Road Shiqiao Panyu Guangzhou P R China Tel 86 20 3451 1231 Fax 86 20 8466 2675 e mail info ohmchina com ww...