Battery Installation

 

 

The GTS 900 monitor requires 1(one) 9volt battery. The bat-

tery housing is found on the back of unit.  Slide battery 

cover off and insert only a 9volt battery.

 

 

Only new and valid batteries can be used.  

 

AC adapter available

 

 

Assembly

  

 
The GTS 900 has two options for installation: Free-standing 
installation with footplate and pedestal or wall mounting.  
The most common is the free standing option. 
 

Free Standing Installation 

 

1.  Remove all items from carton and confirm you have re-

ceived all items contained in the “Parts Included List.”

 

2.  Choose a location in the work area that is easily accessi-

ble and safe for both test equipment and users.  

Pedestal Assembly 

1.  Locate the pedestal and the connection wire with banana 

clips on one end and eye blots on the other. 

2.  String the connection wire through the pedestal so that 

the banana clips extend out the top of the pedestal and 

the eye bolts end extend out of the two holes at the bot-

tom of the pedestal. 

 

 

Summary of Contents for GTS900K

Page 1: ...l Footwear Wrist Strap Tester Model GTS900K Instruction Manual T R A N S F O R M I N G T E C H N O L O G I E S L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L Ohm Metrics ...

Page 2: ...on GTS 900 1 Features 1 2 Installation Battery Installation 2 Free Standing Assembly 4 Height Adjustment 5 Wall Mount 5 3 Testing Wrist Strap 6 Footwear 6 4 Specifications 8 5 Parts Included List 8 6 Service and Warranty 9 ...

Page 3: ...n requirements as stated in the ANSI ESD S20 20 Reliable Repeatable Results Accuracy and reliability are key strengths of the GTS 900 Test parameters are standard but can be adjusted to match your own specifications Wrist strap testing is set with the ideal 750 kilohm 10 megohm circuit and a 750 kilogm 100 megohm circuit for accurate testing of foot grounders False alarms disappear and adjustments...

Page 4: ... is the free standing option Free Standing Installation 1 Remove all items from carton and confirm you have re ceived all items contained in the Parts Included List 2 Choose a location in the work area that is easily accessi ble and safe for both test equipment and users Pedestal Assembly 1 Locate the pedestal and the connection wire with banana clips on one end and eye blots on the other 2 String...

Page 5: ...atform over pedestal taking special care to leave 12 of connection wire extending from the bot tom 4 String one line of connection wire along wire grove in the platform and connect the eye bolt to connection point with a nut 6 Repeat with remaining line of connection wire 7 Line up the base of the pedestal with the depression in the platform and return the screws Height Adjustment knob Wire Connec...

Page 6: ...he monitor receptacle on pedestal with the banana plugs extending through the receptacle holes See figure 1 3 Return screws to securely fasten receptacle to pedestal 4 Plug the banana plugs into the corresponding jacks on the back of the monitor 5 Carefully insert monitor into receptacle Banana Jacks Figure 1 ...

Page 7: ... on to any flat stationary surface Frequently the unit is mounted on a table or wall 1 Attach two 2 mounting clips to the back of unit 2 Install two 2 screws 1 1 2 apart leaving 1 4 of screw head from mounting surface 3 Mount the tester on the screws pulling gently down to lock into place 4 Place Footwear platform tester under the mounted unit and connect the eye blots of the connection wire to th...

Page 8: ...ly 5 If either the red LED LOW or the red LED HIGH light and audible alarm sound then check the wrist strap and cord set immediately Footwear Testing For the following testing one must be wearing foot ground ing ESD protection The GTS 900 s dual footwear sensors allows for testing of each foot independently The left foot ESD protection is indicated with the LED lights on the left side and the righ...

Page 9: ...ing properly 5 The green LED located on the RIGHT side of monitor la beled PASS indicates that the RIGHT foot ground is functioning properly 6 If either the red LED LOW or the red LED HIGH light on the LEFT side of monitor and audible alarm sound then check the LEFT foot ground set immediately 7 If either the red LED LOW or the red LED HIGH light on the RIGHT side of monitor and audible alarm soun...

Page 10: ...battery General Power 9v Battery or AC adapter Operation Resistance Bridge Output Six LED indicators and audio signal Accuracy 15 for wrist strap tester 15 for anti static footwear tester GST900 Weight 0 44lbs Dimensions 5 5 3 1 1 5 Parts Included List GTS900 1 GTS 900 tester 2 Foot plate 3 AC adapter 4 2 piece pedestal 5 Connection cord for Foot plate Testing Range and Indication ...

Page 11: ...i dent In no event shall Transforming Technologies be li able for collateral or consequential damages To receive service under warranty please contact Transforming Technologies Technical Support About Transforming Technologies Since 1998 Transforming Technologies has helped electronic manufacturing facilities to protect their prod ucts and processes from the many serious problems as sociated with ...

Page 12: ...3719 King Rd Toledo OH 43617 P 419 841 9552 F 419 841 3241 info transforming technologies com ...